A heat transfer oil (specific heat -0.454 kcal/kg °C) leaving a hydraulic system at a rate of 10,000 kg/h at 85°C has to be cooled to 50°C before it can be circulated back to the system. It is desired to determine whether an existing 1-2 pass exchanger having an area of 15 m² would be suitable. Water is available at 30°C and must not be heated to above 38°C. An overall heat transfer coefficient (including the dirt factor) of 400 kcal/h m² °C can be attained in the exchanger. Water flows through the shell and the oil through the tubes. How will the heat transfer rate and the exit oil temperature be affected if the water flow rate is increased by 20%? The overall heat transfer coefficient U is assumed to remain unchanged.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
A heat transfer oil (specific heat = 0.454 kcal/kg °C) leaving a hydraulic system
at a rate of 10,000 kg/h at 85°C has to be cooled to 50°C before it can be circulated back to the
system. It is desired to determine whether an existing 1-2 pass exchanger having an area of
15 m² would be suitable. Water is available at 30°C and must not be heated to above 38°C. An
overall heat transfer coefficient (including the dirt factor) of 400 kcal/h m² °C can be attained in
the exchanger. Water flows through the shell and the oil through the tubes.
How will the heat transfer rate and the exit oil temperature be affected if the water flow rate
is increased by 20%? The overall heat transfer coefficient U is assumed to remain unchanged.
Transcribed Image Text:A heat transfer oil (specific heat = 0.454 kcal/kg °C) leaving a hydraulic system at a rate of 10,000 kg/h at 85°C has to be cooled to 50°C before it can be circulated back to the system. It is desired to determine whether an existing 1-2 pass exchanger having an area of 15 m² would be suitable. Water is available at 30°C and must not be heated to above 38°C. An overall heat transfer coefficient (including the dirt factor) of 400 kcal/h m² °C can be attained in the exchanger. Water flows through the shell and the oil through the tubes. How will the heat transfer rate and the exit oil temperature be affected if the water flow rate is increased by 20%? The overall heat transfer coefficient U is assumed to remain unchanged.
Expert Solution
steps

Step by step

Solved in 5 steps with 4 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The