Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 3 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The function of Copper shading band in induction type energy meter is to ensure flux produced by potential coil is exactly in quadrature with supply voltage. Select one: True Falsearrow_forwardQ2/A: A 100 MW power station delivers 100 MW for 2 hours, 50 MW for 6 hours and is shut down for the rest of each day. It is also shut down for maintenance for 45 days each year. Calculate its annual load factor and then draw the load and load duration curves. D6-arrow_forward3.) A 3-phase synchronous generator, rated 16 kV and 200 MVA, has negligible losses and synchronous reactance of 1.65 per unit. It is operated on an infinite bus having a voltage of 15 kV and delivers 100 MVA at 0.8 pf lagging. Solve the internal voltage. Subject Electrical machine 2arrow_forward
- A synchronous generator is feeding its rated power of 250 MW to a large 60 Hz network over a double circuit transmission The maximum steady state power that can be transmitted over the line with both circuits in service is 500 MW and is 350 MW with any one out of service. A solid three-phase fault occurring at the network-end of one of the lines causes it to trip. If inertia constant is H = 3.5 s, calculate the critical clearing angle and critical clearing time in which the circuit breakers must trip so that synchronism is preserved.arrow_forward7. Two 440V, 60Hz, 6 pole, 30 AC generators are running in parallel. The first supplies the busbars with 525kW of power at a power factor of 0.79 lagging. The second provides the busbars with 415kW at a power factor of 0.96 lagging. An additional load that requires 275kW at a power factor of 0.89 leading is added to the busbars. The two generators have their governor and magnetization controls adjusted so they provide 440V, 60Hz and share the active and reactive powers equally. What is the active and reactive power produced by each and their line currents and speeds?arrow_forwardA 15,000 KVA, 6.9 KV generator, star connected has positive, negative and zero sequence reactances of 0.25, 0.25 and 0.08 p.u. respectively. A reactor of 0.06 p.u. reactance on the generator rating is placed in the line from neutral to ground: A double line to ground fault occurs at the terminals of the generator when it is operating at its rated voltage and unloaded. Find the unitial r.m.s. line and ground wire current for a solidly grounded fault, and also the voltage to ground of the unfaulted line. (UPSC-1975) Ans: 1-1,-4970 A; I, 5480 A; V. 69.7 KVarrow_forward
- A 3.3 kV/110 V, 50 Hz, single-phase trans- former is to have an approximate e.m.f. per turn of 22 V and operate with a maximum flux of 1.25 T. Calculate (a) the number of primary and secondary turns, and (b) the cross- sectional area of the corearrow_forwardplease help me answer thisarrow_forward32. The incremental cost characteristics of two generators delivering a load of 200 MW are as follows: dF = 2.0 + 0.01 P, dP, dP dF, -= 1.6 + 0.02 P, For economic operation the generators P, and P, should be (a) 120 MW and 80 MW (b) 81 MW and 120 MW (c) 120 MW and 120 MW (d) 80 MW and 80 MWarrow_forward
- Q3/ For the system shown in figure. The generator is supplying 1.0 pu MW power under prefault condition. When three-phase fault occur at point F. What should the value of fault reactance must be to make the critical clearing angle equal to 58.9. Sc j0.1 j0.1 10.21 BE j0.38 38 j0.21 IEgl-12 pu 10.19 F 10.19 IVI-1.00 pu j0.1 j0.1 Q4/ Figure below shows the one-line diagramarrow_forwardA power transmission line of 33kV (maximum) carries a maximum current of 1200A is connecting the two areas. A PMMC voltmeter of (0-600V) range and a PMMC ammeter of (0-25A) range are to be used for measurement of voltage and currents of the transmission line. 1.Design and draw a circuit with suitable instrument transformers for the measurement. Use sample values for winding turns. 2.On a particular day, the readings shown by the meters were 17.5A and 440V. Calculate the actual voltage and current in the transmission line.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,