A 400 V, 4-pole, 1450 rpm, 50 Hz wound-rotor induction motor has the following circuit model parameters. R1 = 0.3 Ω; R2 = 0.25 Ω; X1 = X2 = 0.6 Ω; Xm = 35 Ω (a) Calculate the starting torque and current when the motor is started direct on full voltage. (b) Find the slip for maximum torque.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter32: Three-phase Motors
Section: Chapter Questions
Problem 6RQ: Name three factors that determine the torque produced by an induction motor.
icon
Related questions
Question
A 400 V, 4-pole, 1450 rpm, 50 Hz wound-rotor induction motor has the following circuit model parameters. R1 = 0.3 Ω; R2 = 0.25 Ω; X1 = X2 = 0.6 Ω; Xm = 35 Ω (a) Calculate the starting torque and current when the motor is started direct on full voltage. (b) Find the slip for maximum torque.