A 300 mm X 550 mm reinforced concrete edge beam is monolithically casted to a 120 mm slab. The beam is an exterior beam reinforced with 5 - 028 mm bars for tension and ø10 mm bars for stirrups. If a ø100 mm and a 075 mm pipe pass through the beam's cross-section, the center of the pipe is located 120 mm and 140 mm, respectively from the top of the flange. Determine the following using an f'c = 21 MPa and fy = 414 MPa: a. Use NSCP 2015 to layout the reinforcement of this beam. i. The overhanging flange width, if the depth of compression block is just enough to include the two pipes. ii. Ultimate Moment Capacity of the Beam Balanced Steel Ratio ii. iv. Centroid of the Beam's Cross Section neglecting the reinforcement.

Materials Science And Engineering Properties
1st Edition
ISBN:9781111988609
Author:Charles Gilmore
Publisher:Charles Gilmore
Chapter12: Composite Materials
Section: Chapter Questions
Problem 12.7P: Estimate the transverse tensile strength of the concrete in Problem 12.6.
icon
Related questions
icon
Concept explainers
Question
A 300 mm X 550 mm reinforced concrete edge beam is monolithically
casted to a 120 mm slab. The beam is an exterior beam reinforced with
5 - 028 mm bars for tension and 010 mm bars for stirrups. If a Ø100 mm
and a 075 mm pipe pass through the beam's cross-section, the center of
the pipe is located 120 mm and 140 mm, respectively from the top of the
flange. Determine the following using an f'c = 21 MPa and fy =
414 MPа:
a. Use NSCP 2015 to layout the reinforcement of this beam.
i.
The overhanging flange width, if the depth of compression
block is just enough to include the two pipes.
ii.
Ultimate Moment Capacity of the Beam
Balanced Steel Ratio
iii.
iv.
Centroid of the Beam's Cross Section neglecting the
reinforcement.
Transcribed Image Text:A 300 mm X 550 mm reinforced concrete edge beam is monolithically casted to a 120 mm slab. The beam is an exterior beam reinforced with 5 - 028 mm bars for tension and 010 mm bars for stirrups. If a Ø100 mm and a 075 mm pipe pass through the beam's cross-section, the center of the pipe is located 120 mm and 140 mm, respectively from the top of the flange. Determine the following using an f'c = 21 MPa and fy = 414 MPа: a. Use NSCP 2015 to layout the reinforcement of this beam. i. The overhanging flange width, if the depth of compression block is just enough to include the two pipes. ii. Ultimate Moment Capacity of the Beam Balanced Steel Ratio iii. iv. Centroid of the Beam's Cross Section neglecting the reinforcement.
Expert Solution
steps

Step by step

Solved in 2 steps with 6 images

Blurred answer
Knowledge Booster
Design criteria for structural loading
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Materials Science And Engineering Properties
Materials Science And Engineering Properties
Civil Engineering
ISBN:
9781111988609
Author:
Charles Gilmore
Publisher:
Cengage Learning