A 3-phase, 2-pole, round-pole, star-connected synchronous generator with a synchronous reactance of 10 Ohm works in parallel to a 50Hz infinitely powerful network with an interphase voltage of 400V. (Mechanical losses and armature resistance will be neglected. The machine is magnetically linear, no saturation) first case: The generator transmits 1100-j100[VA] complex apparent power to the grid. a)Write the load angle second case: second case: After these operating conditions, the driving torque of the generator is increased 4 times without changing the excitation current (T2=4*T1). b)Write down the new load angle of the generator. (in degrees, include the sign.) c)In this new study, write the angle of the current that the generator will give to the mains according to the mains voltage (degrees forward - backward or +/- by specifying the sign).
Load flow analysis
Load flow analysis is a study or numerical calculation of the power flow of power in steady-state conditions in any electrical system. It is used to determine the flow of power (real and reactive), voltage, or current in a system under any load conditions.
Nodal Matrix
The nodal matrix or simply known as admittance matrix, generally in engineering term it is called Y Matrix or Y bus, since it involve matrices so it is also referred as a n into n order matrix that represents a power system with n number of buses. It shows the buses' nodal admittance in a power system. The Y matrix is rather sparse in actual systems with thousands of buses. In the power system the transmission cables connect each bus to only a few other buses. Also the important data that one needs for have a power flow study is the Y Matrix.
Types of Buses
A bus is a type of system of communication that transfers data between the components inside a computer or between two or more computers. With multiple hardware connections, the earlier buses were parallel electrical wires but the term "bus" is now used for any type of physical arrangement which provides the same type of logical functions similar to the parallel electrical bus. Both parallel and bit connections are used by modern buses. They can be wired either electrical parallel or daisy chain topology or are connected by hubs which are switched same as in the case of Universal Serial Bus or USB.
A 3-phase, 2-pole, round-pole, star-connected synchronous generator with a synchronous reactance of 10 Ohm works in parallel to a 50Hz infinitely powerful network with an interphase voltage of 400V. (
first case: The generator transmits 1100-j100[VA] complex apparent power to the grid.
a)Write the load angle second case:
second case: After these operating conditions, the driving torque of the generator is increased 4 times without changing the excitation current (T2=4*T1).
b)Write down the new load angle of the generator. (in degrees, include the sign.)
c)In this new study, write the angle of the current that the generator will give to the mains according to the mains voltage (degrees forward - backward or +/- by specifying the sign).
Trending now
This is a popular solution!
Step by step
Solved in 7 steps with 1 images