8. The total power supplied to a balance delta load is found in the same way as for a balance wye load.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.7P: Let a 100V sinusoidal source be connected to a series combination of a 3 resistor, an 8 inductor,...
icon
Related questions
icon
Concept explainers
Question
8. The total power supplied to a balance delta load is found in the same way as for a
balance wye load.
True
False
Either
Neither
12. A load of 20 + j35 ohms is connected across a 220 V, 60 Hz supply. Find the
reactive power of the load in var.
595
2420
1042
1382
13. A type of DC source where the characteristic output voltage has perfect
unidirectional waveform and is based on electrochemical principle.
Generator
Inverter
Converter
Battery
14. Calculate the Rf of a circuit whose impedance is 20+j35 and current of 2A.
0.86
0.91
0.50
0.71
15. What capacitor shall be installed in parallel with a circuit to achieve a unity power
factor if the reactive power of a circuit is 200VARS and the voltage is 100V.
80.45 microfarad
53.05 microfarad
It's already in unity
62.45 microfarad
Transcribed Image Text:8. The total power supplied to a balance delta load is found in the same way as for a balance wye load. True False Either Neither 12. A load of 20 + j35 ohms is connected across a 220 V, 60 Hz supply. Find the reactive power of the load in var. 595 2420 1042 1382 13. A type of DC source where the characteristic output voltage has perfect unidirectional waveform and is based on electrochemical principle. Generator Inverter Converter Battery 14. Calculate the Rf of a circuit whose impedance is 20+j35 and current of 2A. 0.86 0.91 0.50 0.71 15. What capacitor shall be installed in parallel with a circuit to achieve a unity power factor if the reactive power of a circuit is 200VARS and the voltage is 100V. 80.45 microfarad 53.05 microfarad It's already in unity 62.45 microfarad
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning