Question
thumb_up100%
Subject: Electrical Circuit (EE2)
***Need asap pls. Thank you.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The instantaneous power absorbed by the load in a single-phase ac circuit, for a general R LC load under sinusoidal-steady-state excitation. is (a) Nonzero constant (b) Zero (c) Containing double-frequency componentsarrow_forwardelectrical engineering department plzz solvearrow_forwardThe circuit shows an unbalanced electrical installation powered by a positive sequence symmetrical three-phase network of 380 V compound voltage. The loads are single phase. Load 1 absorbs an active power of 950 W with f.d.p. 0.5 inductive. Load 2 absorbs an active power of 1,140 W with f.d.p. Unit. Load 3 absorbs from the network an active power of 760 W with f.d.p. 0.5 capacitive. Taking the network voltage URN as the phase reference, calculate: a) complex expressions of the line currents IR. Is. and ITarrow_forward
- 2) Figure shows three loads connected in parallel across a 1000-V (rms), 60-Hz single-phase source. Load 1: Inductive load, ... kVA, 0.28 p.f. lagging Load 2: Capacitive load, ... kW, 40 kvar Load 3: Resistive load, 15 kW Determine the total (a) kW, (b) kvar, (c) kva, and (d) supply power factor. (Please determine the power values within the specified limits: Load 1 apparent power: 100-150 kVA, Load 2 active power: 5-20 kW. By considering the power values you determined yourself, solve the question.) Load Load DE 1 2 Load 3arrow_forwardPlease help with the solution.arrow_forwardHi, Help me with this circuit questionarrow_forward
- 5arrow_forwardTranskrmers phase with each bank with - adjuste 35. Three single-phase transformers, cach of 100 kVA rating, are conected in a closed-delta arrangement. If one of them is taken out, it would be possible to load the bank in such a manner that cach one is loaded to the extent of: A 86.6 kVA C. 57.7KVA B. 66.7 kVA D. 33.33 kVA when load is at unity power factor. 36. Average power factor at which V-V bank separate is A 86.6% C. 66.67% В. 73.3% D. None of these 37. Scott connections are used for: A. single-phase to three-phase transformation C. three-phase to two-phase transformation B. three-phase to single-phase transformation (D Any of the above 38. The current in low voltage winding of a 25 kVA, 6600/400 V, 50 Hz, 3-phase Y-A transformer, at full load is: A 36 A Č. 65,32 A B. 20.78 A D. 40.2 A 39. The current in high voltage winding of a 20 kVA, 2200/220 V, 50 Hz, 3-phase A-A transformer, at full load is: (A. 3.03 A C. jo.5 A B. 5.25 A D. None of above 40. The current in low voltage…arrow_forwardA three phase load has a rating of 200 KW, 4000 volts, 0.7 power factor lagging and a frequency of 50 Hz. Determine the required capacitor bank rating in micro Farad per phase to improve its power factor to 0.9 lagging if: a) The capacitor bank is to be connected in Delta. b) The capacitor bank is to be connected in Star.arrow_forward
- 5.5 kW, 1450 rpm. L-type equivalent circuit and parameters for a continuous sinusoidal phase of a star connected 3-phase ASM with line voltage 220 V and frequency 50 Hz are given as follows, ignoring core (iron) losses: R1=0.21 Ohm, R2=-0.18 Ohm, X1=X2-0.66 Ohm and Xm = 9.9 Ohm How many times the inrush current will be the rated current when the ASM is started directly? Answer options group 8.0815 2.6455 4.3763 7.1534 1.2558 6.3414 5.2280 3.7473arrow_forwardWhich of the following descriptions IS NOT correct for loads in power systems? A. The purely resistive load absorbs the real power from the power grid B. The purely inductive load absorbs the positive reactive power from the power grid C. The purely capacitive load absorbs the positive reactive power from the power grid. D. The average value of the instantaneous power through loads is equal to its real power. In an ac circuit, power factor correction or improvement is achieved by A. Connecting a resistor in parallel with the inductive load B. Connecting an inductor in parallel with the inductive load C. Connecting a capacitor in parallel with the inductive load A balanced delta-load can be converted to an cquivalent balanced wye- load by dividing the delta-load impedance by A. square root of 3 В.3 C. 1/3arrow_forwardThe three-phase source line-to-neutral voltages are given by Ean=100,Ebh=10+240, and Ecn=10240volts. Is the source balanced? (a) Yes (b) Noarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning