5. A two-stage double-acting compressor is to deliver 90 lb/min of air from 14.3 psia and 90°F to a final pressure of 185 psia. The normal barometer is 29.8 in. Hg and the temperature is 80°F. The pressure drop in the intercooler is 3 psi and the temperature of the air at the exit of the intercooler is 90°F, the speed is 210 RPM and PV C during compression and expansion. The clearance is 5% for both cylinders. The temperature of the cooling water increases by 18°F. Find (a) volume of free air, (b) discharge pressure of LP cylinder for minimum work, (c) temperature at discharge for both 1.34 =

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter46: Room Air Conditioners
Section: Chapter Questions
Problem 7RQ
icon
Related questions
Question
5. A two-stage double-acting compressor is to deliver 90 lb/min
of air from 14.3 psia and 90°F to a final pressure of 185 psia.
The normal barometer is 29.8 in. Hg and the temperature is
80°F. The pressure drop in the intercooler is 3 psi and the
temperature of the air at the exit of the intercooler is 90°F, the
speed is 210 RPM and PV 1.34 C during compression and
expansion. The clearance is 5% for both cylinders. The
temperature of the cooling water increases by 18°F. Find (a)
volume of free air, (b) discharge pressure of LP cylinder for
minimum work, (c) temperature at discharge for both
cylinders, (d) mass of cooling water to be circulated about
each cylinder and through the intercooler, (e) the work of
compression, (f) if for LP cylinder, L/D 0.68 and if both
cylinders have the same stroke, what are the bore and stroke
for each cylinder?
=
=
Transcribed Image Text:5. A two-stage double-acting compressor is to deliver 90 lb/min of air from 14.3 psia and 90°F to a final pressure of 185 psia. The normal barometer is 29.8 in. Hg and the temperature is 80°F. The pressure drop in the intercooler is 3 psi and the temperature of the air at the exit of the intercooler is 90°F, the speed is 210 RPM and PV 1.34 C during compression and expansion. The clearance is 5% for both cylinders. The temperature of the cooling water increases by 18°F. Find (a) volume of free air, (b) discharge pressure of LP cylinder for minimum work, (c) temperature at discharge for both cylinders, (d) mass of cooling water to be circulated about each cylinder and through the intercooler, (e) the work of compression, (f) if for LP cylinder, L/D 0.68 and if both cylinders have the same stroke, what are the bore and stroke for each cylinder? = =
Expert Solution
steps

Step by step

Solved in 7 steps with 13 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning