2. Assume you are an electrical apprentice. The electrical foreman on the job tells you
to connect some equipment grounding conductors to the ground bus that runs along
the front bottom of a dead-front switchboard. The system is 480Y/277-volt solidly
grounded wye. The building is still under construction, and a number of other trades
are working in the building. The switchboard has already been energized, and it is
totally enclosed except for two access covers near the front bottom where the ground
bus runs. The ground bus already has the proper number of and size of lugs for the
equipment grounding conductors. You ask permission to turn off the main power so
that you can work on connecting the equipment grounding conductors to the ground
bus without having to worry about accidentally touching the phase buses with your
hands or with a screwdriver or wrench. The foreman says, “No.” What would you do?
to generate a solution
a solution
- 13. Two electricians are discussing feeders that supply branch circuits. Electrician A says that the AHJ canrequest a drawing that indicates conductor size and other details. Electrician B says that a GFPE must beincluded as part of the 500A feeder disconnect. Which of the following statements is correct?A. Both electricians are correct.B. Neither electrician is correct.C. Only Electrician A is correct.D. Only Electrician B is correct.arrow_forwardof p o How many conductors enter the ceiling fan/light wall box? Switch ond out let boxes s tirst 10. What type and size of box may be used for the ceiling fan/light wall box?. 11. What type of covers are used with 4 in. square outlet boxes? 12. a. Does the circuit for the Master Bedroom have a grounded circuit conductor? b. Does it have an equipment grounding conductor? c. Explain the difference between a "grounded" conductor and an "equipment grounding" conductor. 13. Approximately how many feet (meters) of 2-wire cable and 3-wire cable are needed to ft complete the circuit supplying the Master Bedroom? Two-wire cable: ft (- m). m). Three-wire cable: 14. If the cable is laid in notches in the corner studs, what protection for the cable must be provided? 15. How high are the receptacles mounted above the finished floor in this bedroom? 16. Approximately how far from the bedroom door is the first receptacle mounted? (See the plans.) 17. What is the distance from the finished floor to…arrow_forwardh.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0. h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.arrow_forward
- What happens in a multi-wire branch circuit when the grounded (neutral) opens or becomes disconnected? Select one: a. an arc fault occurs b. current rises c. voltage rises d. nothing happensarrow_forwardYou just moved into a new house and notice that the bathroom light and hall light will not turn on unless the switch for both lights is in the on position. What can you conclude about the lights? a. The hall light and bathroom light are wired in parallel. b. The light switch for the bathroom resets a breaker for both lights C. The hall light and bathroom light are wired in series. d. The hall light and bathroom light must have two separate power sources. e. Two of the above.arrow_forward12. A short circuit describes the condition where there's contact between theA. hot wire and the neutral wire.B. grounded conductor and the grounding wire.C. hot wire and the grounding wire.D. neutral wire and the grounded conductor. I'm not sure if it's the letter A or C, could you help me with the correct answer.arrow_forward
- You are an electrician working in an industrial plant. The company is constructing a maintenance shop located 225 feet from the main plant electrical system. You are to install a 400-ampere three-phase wire system in the new maintenance shop. The service is supplied by the existing plant service. The voltage is 480 volts and the voltage drop is to be kept at 3% or below at full load. The conductors are to be aluminum. What size conductors should be installed for the new service? Express your answer to the nearest standard wire size. (Note: Determine the wire size by calculating length, resistance, and voltage drop as opposed to using the National Electrical Code.)arrow_forward1. Electric utility installations and equipment under the exclusive control of the utility donot have to conform to the National Electrical Code. However, they do have to conform to the . 2. Assume you are an electrical apprentice. The electrical foreman on the job tells youto connect some equipment grounding conductors to the ground bus that runs alongthe front bottom of a dead-front switchboard. The system is 480Y/277-volt solidlygrounded wye. The building is still under construction, and a number of other tradesare working in the building. The switchboard has already been energized, and it istotally enclosed except for two access covers near the front bottom where the groundbus runs. The ground bus already has the proper number of and size of lugs for theequipment grounding conductors. You ask permission to turn off the main power sothat you can work on connecting the equipment grounding conductors to the groundbus without having to worry about accidentally touching the phase buses…arrow_forwardIf the cable in Figure ran for the whole of its length, grouped with others of the same size in a high ambient temperature, and was totally surrounded with thermal insulation, The correction factors considered will be----------- Fuseboard High ambient temperature Cable Grouping of cables Thermal insulation Load BS 3036 fuse O a. Cg O b. All Ca,Cg.Ci and Cf O c. Ci O d. Caarrow_forward
- QUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forwardElectrical plants Define the terms "Main column ." " Line ." " Protection earth " and " Operating eartharrow_forwardWe are running 3 wires in an IMC to a control panel with a 150 amp circuit breaker disconnect in the control panel. The conduit is run 12 inches above the roof on a strut rack. The ambient air temperature is 88 degrees. This control panel feeds the #1 cooling fan. What sized ungrounded conductors do we need? All conductors have typeTHHN insulation. A #1 AWG B 100 Kcmil C #1/0 AWG D #10 AWG What sized IMC do we need? A 3/4" B 1 1/4" C 1" D 1 1/2"arrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning