100 300 H 4.8 kPa surcharge floor load Pp = 600 kN PL = 800 kN C L MD = 20 kN-m M₁ = 30 kN-m 16-mm-diameter longitudinal bars and dowels 16-mm-dia. bars 75 clear cover An architectural requirement of 375 mm by 375 mm column is provided. The design loads supported by the column from structural analysis are as follows: Dead Loads: Axial Load Reaction P 600 kN Internal Moment Reaction M 20 kN-m Live Loads: Axial Load Reaction P Internal Moment Reaction M 800 kN 30 kN-m The NSCP C101-15 Table 405.3.1 applicable load combinations are: U U 1.4D 1.2D + 1.6L The reinforced concrete material strengths are as follows [NSCP C101-15 Sec. 419.2.1.1 and Table 420.2.2.4(a)]: Se Sy 28 MPa at 28 days 420 MPa and uncoated steel It is required to design the square tied column and the supporting square spread footing. Use 16-mm-diameter steel reinforcement following ASTM A615. The dowels may be required to carry some of the column load across the column-footing interface. The top of the footing will be covered with 300 mm backfill soil with a density of 16 kN/m³, and a 100-mm-thick basement floor. The basement floor load is 4.8 kPa and serves as a surcharge. For shallow foundations, the allowable bearing pressure is 290 kPa for medium stiff clay soil.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
A square spread footing supports a square tied column as shown. Assume that the reinforced concrete is normal weight (24 kN/m3) and = 1.00 (NSCP C101-15 Table 419.2.4.2). The column has a height of 3.5 meters. 1. Compute the development length ld (mm) of the column reinforcement embedded to the spread footing. It is permitted to set Ktr = 0. 2. Determine the required number N of dowel bars which carry some of the column load across the column-footing interface.
100
300
H
4.8 kPa surcharge
floor load
Pp =
600 kN
PL
= 800 kN
C
L
MD = 20 kN-m
M₁ = 30 kN-m
16-mm-diameter
longitudinal bars
and dowels
16-mm-dia. bars
75 clear
cover
Transcribed Image Text:100 300 H 4.8 kPa surcharge floor load Pp = 600 kN PL = 800 kN C L MD = 20 kN-m M₁ = 30 kN-m 16-mm-diameter longitudinal bars and dowels 16-mm-dia. bars 75 clear cover
An architectural requirement of 375 mm by 375 mm column is provided. The design loads supported by the column from structural analysis are as follows:
Dead Loads:
Axial Load Reaction P
600 kN
Internal Moment Reaction M
20 kN-m
Live Loads:
Axial Load Reaction P
Internal Moment Reaction M
800 kN
30 kN-m
The NSCP C101-15 Table 405.3.1 applicable load combinations are:
U
U
1.4D
1.2D + 1.6L
The reinforced concrete material strengths are as follows [NSCP C101-15 Sec. 419.2.1.1 and Table 420.2.2.4(a)]:
Se
Sy
28 MPa at 28 days
420 MPa and uncoated steel
It is required to design the square tied column and the supporting square spread footing. Use 16-mm-diameter steel reinforcement following ASTM A615. The dowels may
be required to carry some of the column load across the column-footing interface. The top of the footing will be covered with 300 mm backfill soil with a density of 16
kN/m³, and a 100-mm-thick basement floor. The basement floor load is 4.8 kPa and serves as a surcharge. For shallow foundations, the allowable bearing pressure is 290 kPa
for medium stiff clay soil.
Transcribed Image Text:An architectural requirement of 375 mm by 375 mm column is provided. The design loads supported by the column from structural analysis are as follows: Dead Loads: Axial Load Reaction P 600 kN Internal Moment Reaction M 20 kN-m Live Loads: Axial Load Reaction P Internal Moment Reaction M 800 kN 30 kN-m The NSCP C101-15 Table 405.3.1 applicable load combinations are: U U 1.4D 1.2D + 1.6L The reinforced concrete material strengths are as follows [NSCP C101-15 Sec. 419.2.1.1 and Table 420.2.2.4(a)]: Se Sy 28 MPa at 28 days 420 MPa and uncoated steel It is required to design the square tied column and the supporting square spread footing. Use 16-mm-diameter steel reinforcement following ASTM A615. The dowels may be required to carry some of the column load across the column-footing interface. The top of the footing will be covered with 300 mm backfill soil with a density of 16 kN/m³, and a 100-mm-thick basement floor. The basement floor load is 4.8 kPa and serves as a surcharge. For shallow foundations, the allowable bearing pressure is 290 kPa for medium stiff clay soil.
Expert Solution
steps

Step by step

Solved in 2 steps with 4 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning