1. Three 1-phase transformers, connected delta-delta, supply a balanced 3-phase load of 1200 kW at 4400 V at 0.8 p.f. lagging. Transformers are supplied from 3- phase mains at 11000 V. Find the currents in the primary and secondary winding of the transformer. 2. When the transformer is supplied at 400 V, 50-hz the hysteresis loss is found to be 300 W and eddy current loss is 250 W. Determine the eddy current loss when the transformer is supplied at 800 V, 100-hz.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.63P: A 23/230-kV step-up transformer feeds a three-phase transmission line, which in turn supplies a...
icon
Related questions
Question
100%
1. Three 1-phase transformers, connected delta-delta, supply a balanced 3-phase
load of 1200 kW at 4400 V at 0.8 p.f. lagging. Transformers are supplied from 3-
phase mains at 11000 V. Find the currents in the primary and secondary winding
of the transformer.
2. When the transformer is supplied at 400 V, 50-hz the hysteresis loss is found to
be 300 W and eddy current loss is 250 W. Determine the eddy current loss when
the transformer is supplied at 800 V, 100-hz.
Transcribed Image Text:1. Three 1-phase transformers, connected delta-delta, supply a balanced 3-phase load of 1200 kW at 4400 V at 0.8 p.f. lagging. Transformers are supplied from 3- phase mains at 11000 V. Find the currents in the primary and secondary winding of the transformer. 2. When the transformer is supplied at 400 V, 50-hz the hysteresis loss is found to be 300 W and eddy current loss is 250 W. Determine the eddy current loss when the transformer is supplied at 800 V, 100-hz.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning