1. For Figure 1: The 34 source on the left delivers power to a 30 load via conductors with an impedance of (6+j8) 2 per line. The magnitude of the line-to-line voltages at the source side and at the load side are 120 and 110 kV, respectively. If the power factor of the load is 0.90 lagging, determine (a) the currents (magnitude and angle) and voltages (magnitude and angle) of the 30 load. (Hint: Voltage at the source side and the load side have given magnitude but different angles. Assume the load is Y-connected and use its Van as the reference.)

Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter7: Alternating Current, Power Distribution, And Voltage Systems
Section: Chapter Questions
Problem 7RQ
icon
Related questions
Question
120 kV
Fig. 1
۸ جمعت
حمت
Z= 6 + j8 92
110 kV
Balanced
3-phase
load
Transcribed Image Text:120 kV Fig. 1 ۸ جمعت حمت Z= 6 + j8 92 110 kV Balanced 3-phase load
1. For Figure 1: The 30 source on the left delivers power to a 30 load via conductors with an impedance of (6+j8)
per line. The magnitude of the line-to-line voltages at the source side and at the load side are 120 and 110
kV, respectively. If the power factor of the load is 0.90 lagging, determine (a) the currents (magnitude and
angle) and voltages (magnitude and angle) of the 30 load. (Hint: Voltage at the source side and the load side
have given magnitude but different angles. Assume the load is Y-connected and use its Van as the reference.)
Transcribed Image Text:1. For Figure 1: The 30 source on the left delivers power to a 30 load via conductors with an impedance of (6+j8) per line. The magnitude of the line-to-line voltages at the source side and at the load side are 120 and 110 kV, respectively. If the power factor of the load is 0.90 lagging, determine (a) the currents (magnitude and angle) and voltages (magnitude and angle) of the 30 load. (Hint: Voltage at the source side and the load side have given magnitude but different angles. Assume the load is Y-connected and use its Van as the reference.)
Expert Solution
steps

Step by step

Solved in 4 steps with 11 images

Blurred answer
Knowledge Booster
Sinusoids and Phasors of Alternating Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning