Heating Inspecion II - Test 3

pdf

School

Academy of Learning *

*We aren’t endorsed by this school

Course

1306050

Subject

Mechanical Engineering

Date

Dec 6, 2023

Type

pdf

Pages

29

Report

Uploaded by MegaOwl3827

11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser Due No due date Points 50 Questions 50 Time Limit 60 Minutes Requires Respondus LockDown Browser This quiz is currently locked. Attempt History Attempt Time Score LATEST Attempt 1 35 minutes 38 out of 50 (D Correct answers are hidden. Score for this quiz: 38 out of 50 Submitted Nov 11 at 9:10pm This attempt took 35 minutes. Question 1 1/1 pts All of the following are advantages of electric heat except electric furnaces have larger capacity than gas or oil heat furnaces room by room control is possible electric heating systems are less expensive to purchase and install than gas or oil systems electric heat is quick to respond https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 1/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... there are almost no off-cycle losses : Please refer to Section 2.2. Question 2 1/1 pts The distribution piping in a steam system may contain all of the following except air water steam condensate exhaust . Please refer to Section 2.2. Question 3 1/1 pts Which of the following was not a common radiant ceiling heating system? panels laid on top of ceilings below insulation wires embedded in lightweight concrete https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 2/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... wires embedded in lightweight plaster pre-wired panels wires embedded between two layers of drywall : Please refer to Section 7.0. neorrest Question 4 0/1pts How far above electric baseboards heaters should drapes typically be hung? 3 inches 5 inches 7 inches 9 inches 12 inches : Please refer to Section 4.1.2. Question 5 1/1 pts Why don't we want electrical receptacles located above heaters? https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 3/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... the circuit is likely to be overloaded the fuse is likely to be undersized an electrical cord resting on a heater poses a fire hazard whatever is plugged into the receptacle will obstruct the heater the receptacle will be too hot to touch when plugging in an appliance : Please refer to Section 4.1.4. neerrest Question 6 0/1 pts Which types of electric heating systems should be removed from houses? Flex Heat radiant panels convective toe kick heaters radiant panels in drywall ceilings electric furnaces on 240-volt circuits baseboard heaters located on exterior walls below windows : Please refer to Section 7.0. Question 7 171 pts https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 4/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... AnF & T trap is a fast and tall trap a float and thermostatic trap a filling and timing trap only found on one pipe systems located half way up the side of a radiator : Please refer to Section 8.7. Question 8 171 pts A blowdown valve is part of a Hartford Loop Is an automatic water make up device IS used to clean the sight glass is used to test and flush the low water cut out relieves pressures in excess of 30 psi : Please refer to Section 6.0. https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 5/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... Question 9 1/1 pts Where are the air vents in a one pipe parallel flow system typically located? on the radiators at the steam header at the end of the return mains at the Hartford Loop at the radiators and the end of return mains : Please refer to Section 8.5. neerrest - Question 10 0/1 pts Which of the following is not a problem with a wall furnace? the furnace top is 20 inches below the ceiling the vent terminates 8 feet above the bottom of the furnace the vent has a 30° offset an unvented system is located in a bedroom ducts have been provided https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 6/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... : Please refer to Section 3.0. Question 11 171 pts Electric boilers will not have a circulator pump pressure relief valve pressure limit switch draft hood safe fill switch : Please refer to Section 6.0. Question 12 171 pts Which of the following statements is true with respect to wall furnaces? They can always be unvented require a two inch clearance from combustibles on all sides always use outside combustion air use BW Vents https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 7/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... are mid-efficiency appliances : Please refer to Section 3.0. Question 13 11/1 pts A 20 kilowatt 240 volt electric furnace would draw approximately how many amps for the heating elements? 235 43 63 83 103 . Please refer to Section 2.2. Question 14 11/1 pts Which of the following components would you find on a steam system? an expansion tank a high temperature limit switch https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 8/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... a pressure gauge a circulator pump manual bleed valve on the rads : Please refer to Section 3.0. Question 15 171 pts Which one of the following is hot a common problem with space heaters? iInoperative heaters obstructed heaters electrical receptacles beside heaters 120-volt heaters installed on 240-volt circuits thermostats overloaded : Please refer to Section 4.1. Incorrect Question 16 0/1 pts All of the following are types of steam systems except one. Which one is not? https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 9/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... vapor system vacuum system vapor/vacuum system two pipe reverse flow system one pipe reverse flow system : Please refer to Section 2.2. Question 17 171 pts An electric heating system has a heat exchanger a thermocouple a draft hood an overcurrent protection device an induced draft fan : Please refer to Section 2.2. Incorrect | Question 18 0/1 ptS https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 10/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... Which of the following statements is true with respect to room heaters? They can only be radiant systems require 18 inches of clear space above the heater may be installed on combustible floors may be installed in masonry fireplaces may be installed with four inches clearance on all sides : Please refer to Section 5.0. neerrect - Question 19 0/1 pts Why is a 120-volt heater wired as 240-volts a problem? inadequate heat delivery the room will overheat the fuse will be undersized the wire will be oversized the heater may overheat : Please refer to Section 4.1.5. https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 11/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... Question 20 171 pts Which of the following gas heating systems is typically designed to be connected to a duct system? wall furnaces floor furnaces space heaters fireplaces none of the above : Please refer to Section 2.2. Question 21 1/1 pts Which one of the following is not a common electric fan problem? noisy inoperative loose dirty fails to stay on after thermostat is satisfied https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 12/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... : Please refer to Section 4.1.6. Question 22 171 pts The purpose of a Hartford Loop is to equalize pressure throughout the system prevent flooding of the boiler keep dry returns dry prevent water from leaking out of the boiler if the wet return leaks prevent flooding of main vents : Please refer to Section 4.1. Question 23 171 pts Space heaters may be forced air power vented provided with induced draft fans connected to ductwork https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 13/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... connected to piping and heating coils : Please refer to Section 4.0. neerrect Question 24 0/1 pts After you turn an electric baseboard heater on how long should it take for the heater to get warm? less than 10 seconds less than one minute less than 5 minutes less than 10 minutes less than 15 minutes : Please refer to Section 4.1.1. Question 25 11/1 pts Which of the following statements with respect to gas fireplaces is true? all gas fireplaces are decorative only all gas fireplaces have heatilators https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 14/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... gas fireplaces can be rated as space heaters gas fireplaces are very similar to wood burning fireplaces gas fireplaces cannot have glass doors : Please refer to Section 6.0. Question 26 171 pts The purpose of an equalizer pipe in a steam boiler is to allow air to escape from the system so steam can flow to equalize the steam pressure in the supply and return sides of the boiler to equalize water pressure in the supply and return mains to equalize pressure drop from the beginning to end of the system to ensure equal steam pressure is available at all radiators : Please refer to Section 4.1. Question 27 111 pts Which of the following would you typically find on a hot water boiler? https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 156/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... water temperature and pressure gauge water level gauge Pressuretrol equalizer pipe Hartford Loop : Please refer to Section 3.0. Question 28 171 pts Boilers and piping and radiators on steam systems are commonly made of copper cast iron brass copper-nickel alloys aluminum : Please refer to Section 3.0. Question 29 171 pts https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 16/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... What is an appropriate slope for piping in a two pipe steam system? Y2 to 1 inch per foot 1 inch in 2 feet 1 inch in 5 feet 1 inch in 20 feet 1 inch in 50 feet : Please refer to Section 5.3. Question 30 11/1 pts Which of the following steam systems is commonly converted to hot water? a one pipe upfeed system a one pipe downfeed system a two pipe system a one pipe counterflow system a one pipe parallel flow system : Please refer to Section 5.3. https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 17/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... Question 31 171 pts What is the normal setting of a pressure relief valve on a steam system? 1 %2 psi 2 psi S psi 15 psi 30 psi : Please refer to Section 6.0. Question 32 1/1 pts Typical steam pressure in a single family residential steam system would be Y210 5 psi 110 10 psi 2 to 20 psi 3 to 15 psi 5 to 15 psi https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 18/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... : Please refer to Section 4.0. Question 33 171 pts Disadvantages of a steam system include all of the following except missing fan or pump to help move heat through the system the environment inside the pipe is harsher than in a hot water system parts may be difficult to find steam systems are complex because there are so many different kinds of systems and many of them have been modified the temperatures on steam radiators can be high : Please refer to Section 2.2. Question 34 111 pts Steam traps are typically located A) on the radiator in a one pipe system B) on the return pipe from each radiator on a two pipe system C) at the end of the supply main on a two pipe system https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 19/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... D) (a) and (b) E) (b) and (c) : Please refer to Section 8.7. Incorrect Question 35 0 I 1 ptS Most radiant heating systems are located In the ceiling in the floors in the walls on exterior walls below windows In lightweight concrete panels : Please refer to Section 7.0. Incorrect Question 36 0/1 ptS A staged electric furnace uses only the elements required to meet the heat loss has all the elements come on at ten second intervals https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 20/29
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... is always used in combination with an oil furnace is always used in combination with a wood furnace is always part of a heat pump system : Please refer to Section 5.0. Question 37 171 pts When the system is at rest what will you find in the boiler? steam steam and water air and water air and water and steam water : Please refer to Section 4.0. Question 38 1/1 pts All of the following are common electric space heaters except baseboard heaters https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 21/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... wall mounted heaters duct heaters ceiling mounted heaters toe kick heaters : Please refer to Section 4.0. Question 39 111 pts A 20 kilowatt electric furnace has an output BTU/hr capacity of roughly 48 000 BTU/hr 68 000 BTU/hr 88 000 BTU/hr 108 000 BTU/hr 118 000 BTU/hr : Please refer to Section 2.2. Incorrect Question 40 0/1 ptS Gas logs https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 22/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... do not need to be vented may be vented through a chimney should never be installed in an existing fireplace can be used as bathroom heaters must have electronic ignition : Please refer to Section 6.0. Question 41 1/1 pts Which of the following is not a problem on a floor furnace? the heat exchanger cap is missing or damaged The firebox is cracked or rusted There is restricted airflow The unit is not listed certified or approved the thermostat is mounted in the same room as the furnace : Please refer to Section 4.1. Question 42 171 pts https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 23/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... When the heating system is at work what would you expect to find in the radiators? air steam and water steam water air and water : Please refer to Section 4.0. neerrect - Question 43 0/1 pts Which of the following is not true with respect to a floor furnace? the grate should be 6 to 8 inches from any walls the grate should have at least 18 inches clearance on at least two sides the grate should be two inches from doors or drapes or other combustibles the grate should be at least 60 inches below any structure including a bulkhead or stairway https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 24/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... the part of the furnace below the floor level should have at least 12 inches clearance from combustibles on all sides, and 18 inches on control side : Please refer to Section 4.0. Question 44 1/1 pts Ducts for electric furnaces cannot be located in subgrade areas cannot be located in attic areas must be insulated must be electrically grounded are typically larger than ducts for gas or oil furnaces : Please refer to Section 5.0. Question 45 171 pts Which of the following is an acceptable situation with gas fired room heaters? Unvented https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 25/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... fireplace damper not fixed open not labeled for use in a fireplace inadequate combustible clearances no outdoor combustion air supply : Please refer to Section 5.0. Question 46 111 pts A sequencer on an electric furnace is a device that shuts off the furnace when other large electrical appliances in the house are working a control to ensure that individual elements do not all come on at the same time a device that allows the heat produced to match the heat loss of the building a device to ensure that the furnace fan turns on and off at the correct times a device that limits the total current draw of the furnace https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 26/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... : Please refer to Section 5.0. Question 47 1/1 pts All of these devices can cause the boiler to shut off except for one. Which one will not shut the boiler off? pressure relief valve low water cutout Pressuretrol electrical failure cutting off fuel supply : Please refer to Section 6.0. Incorrect Question 48 0/1 pts Clamp-on ammeters may be used on electric furnaces to check the fuse or breaker sizing check the wire sizing check that all the elements come on check the data plate information https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 27/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... check that the furnace blower is working properly : Please refer to Section 5.1.1. Question 49 11/1 pts Common problems with gas fireplace inserts or gas logs include no four inch firebrick no outdoor combustion air intake no ashpit damper in existing fireplace not fixed open not provided with heat circulator : Please refer to Section 6.1.2. Question 50 1/1 pts Which of the following statements about condensate pumps is false? condensate pumps are only used on one pipe systems condensate pumps have an air vent on the receiver condensate pumps have a check valve on the discharge line https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 28/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
11/21/23, 5:29 AM Test 3 - Steam, Electric, Wall & Floor Furnaces, Room Heaters & Gas Fireplaces - Requires Respondus LockDown Browser: Hea... condensate pumps eliminate the need for Hartford Loops condensate pumps do not sense the boiler water level : Please refer to Section 8.8. Quiz Score: 38 out of 50 https://mynew.aolcc.ca/courses/9851/quizzes/29658?module_item_id=722474 29/29
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help