Q) Air conditioning system supplies two rooms required deferent conditions. Room 1 is to be minted at 16 C° dry bu temperature and 75% saturation, by supplying air at 13 C°, whereas room 2 is to be minted at 25 C° and 45% saturation supplying air at the same moisture content as required for room one. There is a commune extract duct the ratio of fre outdoor air to rooms recirculated air be (0.2). Then the mixed air stream passes through a cooled coil which has a cont factor 0.9, then supplying to the rooms through separates heater coil. Determine: a- The mass flow rate of supplying air 1 each room. b- Plot the psychometric chart. c- Obtain the cooler load. d- Obtain the load of each heater. Let the outdc condition is 42 C° dry bulb temperature & 25 % RH. [Room 1 (Qs=5.2 kW, Q=1.3 kW) Room 2 (Qs=4.2 kW, QL-2.8 kW

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter40: Typical Operating Conditions
Section: Chapter Questions
Problem 1RQ: The standard design conditions for air-conditioning systems established by the Air-Conditioning,...
icon
Related questions
icon
Concept explainers
Question
Q) Air conditioning system supplies two rooms required deferent conditions. Room 1 is to be minted at 16 C° dry bu
temperature and 75% saturation, by supplying air at 13 C°, whereas room 2 is to be minted at 25 C° and 45% saturation
supplying air at the same moisture content as required for room one. There is a commune extract duct the ratio of fre
outdoor air to rooms recirculated air be (0.2). Then the mixed air stream passes through a cooled coil which has a cont
factor 0.9, then supplying to the rooms through separates heater coil. Determine: a- The mass flow rate of supplying air
each room. b- Plot the psychometric chart. c- Obtain the cooler load. d- Obtain the load of each heater. Let the outdc
condition is 42 C° dry bulb temperature & 25 % RH. [Room 1 (Qs=5.2 kW, Q=1.3 kW) Room 2 (Qs=4.2 kW, QL=2.8 kW
Transcribed Image Text:Q) Air conditioning system supplies two rooms required deferent conditions. Room 1 is to be minted at 16 C° dry bu temperature and 75% saturation, by supplying air at 13 C°, whereas room 2 is to be minted at 25 C° and 45% saturation supplying air at the same moisture content as required for room one. There is a commune extract duct the ratio of fre outdoor air to rooms recirculated air be (0.2). Then the mixed air stream passes through a cooled coil which has a cont factor 0.9, then supplying to the rooms through separates heater coil. Determine: a- The mass flow rate of supplying air each room. b- Plot the psychometric chart. c- Obtain the cooler load. d- Obtain the load of each heater. Let the outdc condition is 42 C° dry bulb temperature & 25 % RH. [Room 1 (Qs=5.2 kW, Q=1.3 kW) Room 2 (Qs=4.2 kW, QL=2.8 kW
Expert Solution
steps

Step by step

Solved in 4 steps with 8 images

Blurred answer
Knowledge Booster
Chemical and Phase Equilibrium
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning