EXL/ Calculate Cooling load temperfure di fference (CLTD) for Sonth wall from gromPDat 32° North latitude Assume dark Colour,design outoor temperature 35 ,desion Îndoor temperrature TR=25.s, mean outoloor temperature Tm= 29.4 c° and daily range DR=l.6C at hour 14. on october 21. %3D
Q: A certain component is to be carburized to obtain 0.592 wt % C at a depth of 2.0 mm, After…
A:
Q: a, as it is buried from 1 km to 3 km depth, assuming its compaction is in equilibriu sume now that…
A: shale thikness=1 km lise between 1 km to 3 kmArea=(10×10) km2 =100km2Area=108m2volume of water…
Q: Develop preliminary estimate of product yields on the processing of 1000+ RC of 23700 BPD capacity.…
A:
Q: The chart below is for the properties of heat treated AISI 1340, oil quenched and tempered steel.…
A: Given data: - The kind of the steel is AISI 1340.
Q: es can destroy them. Cons at 15°C. A cold front moves ddenly drops to -15°C, with a e properties of…
A:
Q: Repeat Prob. 8-1 for cesium iodide. which has a transmissivity of approximately 0.92 between O.3 and…
A: Given, a. τ=0.9λ1=0.2μmλ2=4μmT=800°C=1073Kλ1T=0.2×1073λ1T=214.6μm.Kλ2T=4×1073λ2T=4292μm.KFraction of…
Q: complete solution Two hundred (200) bags of freshly harvested palay with 23%MC was dried and became…
A:
Q: Differentiate between equillibrium and non equillibrium cooling curve
A: The cooling curve is the graph showing phase change of material with respect to temperature of the…
Q: Consider a material with a specific heat of 480 J/kg-K, a heat of fusion of 0.24×105 J/kg and a heat…
A: Given data: Heat of fusion (Qf) = 0.24*105 J/kg Heat of vaporization (Qv) = 9.4*105 J/kg Need to…
Q: Suppose that on a lincar temperature scale X water boils at -73.6°X and freezes at -195°X. What is a…
A:
Q: Taking into account only the thermal expansion, explain why both the "Block" of the engine (and…
A: The engine block and the piston are made of different materials to allow appropriate amounts of…
Q: Q2) A steel gear is needed to be improved by increasing the carbon content within an outer surface…
A:
Q: 2. Figure shows the cooling curve for aNiO-MgO ceramic. (b) the solidus temperature 2800 2700 2600…
A:
Q: Jsing the equation d = VD · t, where "d' is the layer thickness, "D" is the diffusion coefficient…
A:
Q: Very pure liquid water can be subcooled at atmospheric pressure to temperatures well below 0 °C.…
A:
Q: A thin steel disk of an oil separator of 100mm outside diameter is shrunk onto a solid steel shaft…
A: Solution: Given Data: dD=100 mmds=20 mmN=100000 rev/minE=210 GPaμ=0.3ρ=7850 kg/m3 To Find:…
Q: 27. Start with the one-group neutron diffusion equation and derive the relation for neutron flux in…
A: It has been viewed as that the climate is non-duplicating. In a non-duplicating climate, neutrons…
Q: TOC) P(kPa) u(kJ/kg) Phase description 175 2524.5 325 4000 325 Saturated liquid
A: Given: P= 175 kPa u= 2524.5 kJ/kg Note: Use APPENDIX 1 (PROPERTY TABLES AND CHARTS (SI UNITS))…
Q: From well logging process we got the following records: GR-50, NPHI- 9%, ph- 2.23 gm/ce, At- 70…
A: Porosity of any rock is defined as its capacity to carry fluid.
Q: is represent the relationship between temperature and time O phase diagram O system O cooling curve…
A:
Q: (b) Upper and lower punch is a crucial component that determines the flowability during thixoforming…
A: Characteristics of punch in thixoforming process
Q: After going through the production process, thin plates with a length of 0.5m are cooled by…
A: Given data show in digram:-
Q: Is the Hotelling Rule applicable to oil?
A: Hotelling's hypothesis, often known as Hotelling's rule, states that nonrenewable resource…
Q: A stream of gas flowing at 3000 acfm has a particulate loading of 50 gr/ft3 (grains/cubic foot),…
A: Write the formula for the collection efficiency in terms of particulate loading of the gas. Here,…
Q: I want to know what type of temperature sensor can be used to obtain the melting point temperature…
A: Thermocouples, RTD, and semiconductor-based instruments are used to calculate the temperature of the…
Q: A window with an Rsrvalue of 0.18 receives 300 W/m² of insolation. If the interior of the building…
A: As given that For window RSI- = 0.18 , insolation = 300 W/m2 ; The temperature of the interior Ti=…
Q: A sand mixture was screened through a standard 12 mesh screen. The mass fraction of the oversize…
A:
Q: Find the magnitte omot difection-of theresultant focees? 15 usiny Purtatlogrnm tang
A:
Q: Q3) A steel gear is needed to be improved by increasing the carbon content within an outer surface…
A:
Q: A 5.00-ml. sample of blood was treated with trichloroacetic acid to precipitate proteins. Alter…
A: We know:From beer lambert's law:Absorbance=absorptiviyty×Length×ConcentrationGiven:Standard…
Q: Water has a latent heat of fusion of -334 MJm, surface free energy of 0.195 Jim, and meting point of…
A:
Q: From an experiment, the higher heating value of ethanol was obtained to be 1350 KJ/mol. a. Compute…
A: Ethanol Reaction: C2H5OH(l)+3O2(g)→2CO2(g)+3H2O(l) Given, △E = 1350KJ/mol at 25oC = 298 K…
Q: ...2/ A plant wishes to dry a certain type of fiberboard. To determine drying characteristic, a…
A:
Q: T (°C) Р (кра) u (k]/kg) Phase description 20 5000 150 631.68 225 2000 30 Saturated liquid
A: (1) The internal energy of water at given pressure and temperature is The phase is sub-saturated…
Q: Calculate porosity and water saturation if the formation factor is 15, true formation resistivity 10…
A: In an object or the body the amount of the void space present in percentage is known as the porosity…
Q: Derive Equation 13.3.
A: Consider W1 is the apparent weight of the solid with the sinker submerged, and W2 is the apparent…
Q: The hydraulic conductivity of an aquifer is 0.005 cm/sec, the hydraulic gradient is 0.02, and the…
A: a- the specific discharge is calculated as followq=-KdhdxK=hydraulic conductivity dhdx=hydraulic…
Q: From well logging process we got the following records: GR-50, NPHI= 9%, Ph 2.23 gm/c, At- 70…
A: Given dataBulk density ρb = 2.23gm/cc∆t = 70μsec/ft∆tma =47.5μsec/ftGRmax = 150GRmin = 50TD =…
Q: Draw the cooling curve for steam cooling from 115C to -5 Label each phase (solid, liquid, gas),…
A: Draw a diagram showing the cooling curve with different stages for steam from 115oC to -5oC.
Q: Using the numerical method calculate the steady-state nodal temper- 0 W/m. °C.
A: GIven: TO determine: Temperature at each node
Q: (c) A hardboard wall is exposed to a window on a neighbouring property which is 2 metres high x 2…
A: Laminar flow :Fluid flow in which the adjacent layer of the fluid do not mix with each other and…
Q: 5. Figure shows the cooling curve for ANIO-MgO ceramic. (e) the super heat; 2800 2700 2600 2525 2500…
A: Liquidus temperature: It is a temperature of material above which the material is in complete liquid…
Q: 20 long tons of ice per 12 hrs at -15 °C were produced from steam at 190 °C. If there is no…
A: Refrigeration effect is the amount of heat that is required to extract from the storage space in…
Q: sphere of 15 Cm in diameto is allowed to cool in an 4° An tially at 25 C. It is stmosphenic O°C.…
A: givendiameter of aluminium sphere D=15cminitial temperature Ti=25Coenvironment temperature…
Q: In a drying experiment, a student recorded the mouisture change as below. Answer the following…
A: (a) The critical value of moisture content occurs where the graph can be split into two parts. So,…
Q: 1.Based on the water phase diagram below, which of the 2.)A piping system has water operating at 50…
A: Given: To find : Correct option
Q: A / If the resistance of a copper wire at freezing (0 C°) is 30 , what its resistance at (-40 C°)?…
A:
Step by step
Solved in 2 steps with 1 images
- Q3/ Calculate the cooling load for a ceiling is constructed from 152.4 mm lightweight concrete (I.W concrete) and without a suspended ceiling, dark colour (k-1) and no mechanical ventilation (f = 1). Area= 25 m². The building at 32° North latitude at time 14 on 21 of August, outdoor design temperature 35 °C, daily range DR-11.2 °C and indoor design temperature 25.5 °C.H.WII Cooling Load Estimation An air conditioned room in the Basra city that measures 3 m wide, 3.5 m high and 6 m deep. The window size 1.5 m*1.5 m, mounted on the wall with no external shading and the door size 2m*1m. Calculate the sensible, latent and total heat gains on the room. What is the required cooling capacity? Assume all specification parameters that must be taken into account when calculating cooling load.Please Help me to solve the following physi cal example #1 A Boiler hAS 0.22 m² of net furnace area supported by SA - 36 stay bolts, spuced O.134 by 0.134 m. The mAXimum working pressure is 1, 225 k Pa Calculate: a) diameter of an Stay bolt B) Number of stoybolts re guired Take 3= 114 MPA ond %3D State the paragraph of ASME code used year
- Qigihar House in Heilongiiang Province, China Heat Loss Problems, BSCl 2101 Climate: Avg. remperature is 3.2°C Degree Days is 5000 Inside Air Temp. is 20°C Wall Construction, Inside to Out: 15mm Gypsum Plaster, Sand Aggregate Concrete Block, rectangular core, Sand and Gravi 15mm Cement Plaster, Sand Aggregate All 4 walls measure the same, 8m wide by 7mtall. The house is heated with electricity at a cost of $0.10kWh Calculate the RSI-total for the walls using the tabular method demonstrated in class, and the temperature drop through each element for the January 2.5% temperature. Calculate the rate of heat flow through the wall again for the January 2.5% temperature. Plot the temperature profile approximately to scale through a vertical cross-section of the wall. Calculate the January heating cost for the building. Calculate the annual heating cost for the building. Now add 2" ( 50.8mm ) of extruded polystyrene, smooth skin surface, 35kgm3 rigid insulation to the inside surfaces…Draw and describe the pyhsical construction, internal energy developed as well as the application of the following set of energy level: 1. Blower 2. Steam Pump 3. AC and DC generators2b. List tools which can be used to for minutes ahead forecasting? Compare the geo-thermal technologies used at different 2c. temperatures
- ng/19:HupCeX-7fb1 TjKjAnHHIrQ7-ussXeH9Kbx8 lo-gK_PM1@thread.tacv2 R Search WODOGA Vote 40000 00 Brushes Color Color Edit colors Edit with Paint 30 Shapes Colors Steam is generated at 4.1O MPa and 440C and condensation occurs at 0.105 MPa. Find the thermal efficiency of the cycl the T-S diagram. Draw the schematic diagram andfor the plan shaws the below calculate heating and cooling load for the plan The building should have an orientation (south or north ..... etc.), windows, doors ...... etc. and their locations. Then estimate the cooling and heating loads Latitude angle for Duhok = 37.1(2 (Assume 36) Outdoor design dry bulb temperature for Duhok/ Summer = 46 C Outdoor design wet bulb temperature for Duhok/ Summer = 232]C Outdoor design dry bulb temperature for Duhok/ Winter = - 4]C Outdoor design wet bulb temperature for Duhok/Winter = - 5.3[2]C Inside design conditions / Summer and Winter = 24 ?]C db and 50% RH Daily range =15 C Color correction factor for wall = 0.65 Color correction factor for roof = 0.5 The window having double glazing window Select the suitable materials for the walls and roof. No exterior shading with interior shading Assume the cooling load at 2:00 PM, 21 July as maximum Estimate the cooling and heating loads. Note: Assume any missing data17 lı. 9:08 A docs.google.com 5ialy čhāi For producing 1 ton of crude (pig) iron in blast furnace, the quantity of iron * :ore is 0.65 ton 0.2 ton O 0.05 ton O 1.6 ton O ialy ihäi Refrigerator liners, appliance housings, * :and shower stalls are producing by Injection Molding O Extrusion process O Rotational Molding O Thermoforming O iialy ibai The capacity of a . was from .8 to 30 tons of molten iron Oxygen Convertor Open Hearth O Bessemer Convertor O Electrical furnace O نقطة واحدة The polymer production process which including chemical reaction between two polymer materials - * :thermoset is Rotational Molding O Thermoforming Blow Molding O Reaction Injection Molding O O O O O O O
- Che X Zoho Creator x G GRAPH FOR M X IP IPACCT| Userx E Exergic.in - Or XIP IPACCT | User xG heat transfer X experthiring.chegdindia.com/2Form:Subject_test?privateLink=bF53Pq3tqOdXDb6qq0PKbXBKnU6s212F4b2fdONuXXgZX2DTmglz56EF3A79ha.. equilateral trie x + YouTube M Gmail X Torrent Search Engi... G Google 2 IPACCT | User infor... Adventure Movies -.. 15 My Account OSonalidesigirl Webc. Sarileru Neekevwar. Consider a flow of water in a cylinder maintained at constant temperature of 100° C, the diameter of the cylinder is 50 mm and the length of the tube is 6 m. The inlet and the outlet temperature of the water is T, =15 C and T =57°C. Find the average heat transfer coefficient associated with the flow of water. Mass flow rate is 0.25 kg/s and c, =4.178 kJ/kg K. (A)850 W/m2. K (B 650 W/m2 - K w/m² K (C) 755 W/m² . K (D) 725 W/m² .K 20:02 AO 40 ENG 08-10-2020 Type here to searchQIt is required to air condition a factory building (27mx 18mx4m). The 27m wall is type B and faces south. The following data is available: Two glass windows in south wall 3mx 1.5m each with internal shade, lighting load is 20 Watt fluorescent per m² floor area. The inside air conditions are: 24°C DBT and 50% RH. The outside air conditions are: 40°C DBT, DR-18.0°C and 30°C WBT. Other related data are: Uwall=1.4 W/m² K, Uglass 3.5 W/m² K, Scglass=0.7, occupancy=8 persons doing light bench work and CLF occupancy 0.85. The building is of heavy construction with light color located at 40°N. Calculate the building cooling load from the South wall, windows, lighting and occupancy on August at 4:00 p.m. الاتحادQIt is required to air condition a factory building (27mx 18mx4m). The 27m wall is type B and faces south. The following data is available: Two glass windows in south wall 3mx 1.5m each with internal shade, lighting load is 20 Watt fluorescent per m² floor area. The inside air conditions are: 24°C DBT and 50% RH. The outside air conditions are: 40°C DBT, DR-18.0°C and 30° WBT. Other related data are: Uwall-1.4 W/m² K, Uglass-3.5 W/m² K, Scglass-0.7, occupancy-8 persons doing light bench work and CLF occupancy=0.85. The building is of heavy construction with light color located at 40°N. Calculate the building cooling load from the South wall, windows, lighting and occupancy on August at 4:00 p.m.