To demonstrate the reserve osmosis via membrane separation technology. To evaluate the efficiency of membrane separation process based on reverse osmosis system.   RESULT AND DISCUSSION: Based the result, at time 1 minute, the highest value of conductivity (mS/cm) was at pressure difference 15 bars (14.09mS/cm) and the lowest value of conductivity was at pressure difference 10 bars (10.01mS/cm). After 15 minutes, the highest value of conductivity was at pressure difference 20 bars (15.15mS/cm) and the lowest value of conductivity still at pressure difference 10 bars (14.36mS/cm). The value of the conductivity supposed to increase when the pressure difference increase, which mean at pressure difference 10 bars will have the lowest conductivity value, following by the 15 bars, 20 bars and 25 bars as the highest value of conductivity. This fluctuating value of conductivity was occurred because of the error from membrane filtration unit.   QUESTION What is the general conclusion you can make based on the objective and result,discussion of this experiment?

Materials Science And Engineering Properties
1st Edition
ISBN:9781111988609
Author:Charles Gilmore
Publisher:Charles Gilmore
Chapter10: Oxidation, Degradation, Corrosion, Electroprocessing, Batteries, And Fuel Cells
Section: Chapter Questions
Problem 10.1P
icon
Related questions
Question

EXPERIMENT TITLE: YIELD AND EFFICIENCY DETERMINATION FOR

MEMBRANE SEPARATION PROCESS

OBJECTIVES:

  1. To demonstrate the reserve osmosis via membrane separation technology.
  2. To evaluate the efficiency of membrane separation process based on reverse osmosis system. 

 RESULT AND DISCUSSION:

Based the result, at time 1 minute, the highest value of conductivity (mS/cm) was at pressure difference 15 bars (14.09mS/cm) and the lowest value of conductivity was at pressure difference 10 bars (10.01mS/cm). After 15 minutes, the highest value of conductivity was at pressure difference 20 bars (15.15mS/cm) and the lowest value of conductivity still at pressure difference 10 bars (14.36mS/cm). The value of the conductivity supposed to increase when the pressure difference increase, which mean at pressure difference 10 bars will have the lowest conductivity value, following by the 15 bars, 20 bars and 25 bars as the highest value of conductivity. This fluctuating value of conductivity was occurred because of the error from membrane filtration unit.

 

QUESTION

What is the general conclusion you can make based on the objective and result,discussion of this experiment?

 

Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Fluid materials
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Materials Science And Engineering Properties
Materials Science And Engineering Properties
Civil Engineering
ISBN:
9781111988609
Author:
Charles Gilmore
Publisher:
Cengage Learning