As permitted, installing cables of entirely nonmetallic sheaths into the top of a surface-mounted enclosure through one or more nonflexible raceways, the raceways shall be not less than ________ and not more than __________ in length, provided they meet all of the following conditions: Nonmetallic-sheathed cable secured within __________ in. from where it emerges from the raceway. The raceway comes out of the top of the enclosure and making sure it does not penetrate a ___________ . A fitting is needed at each end of the raceway, and it must remain accessible after the install in order to protect against _____________. Raceways must be _____________ or ___________ to prevent access into the enclosure through the raceway. The cable sheath must be ____________ and extend into the enclosure at least a _____________ in. The raceway must be _____________. When cable(s) are installed in raceways as mentioned above, what NEC Table and Chapter provide guidance on the cable fill require- ments for complete conduit and tubing systems, which this is to be considered. Table _______, Chapter _________.
As permitted, installing cables of entirely nonmetallic sheaths into the top of a surface-mounted enclosure through one or more nonflexible raceways, the raceways shall be not less than ________ and not more than __________ in length, provided they meet all of the following conditions: Nonmetallic-sheathed cable secured within __________ in. from where it emerges from the raceway. The raceway comes out of the top of the enclosure and making sure it does not penetrate a ___________ . A fitting is needed at each end of the raceway, and it must remain accessible after the install in order to protect against _____________. Raceways must be _____________ or ___________ to prevent access into the enclosure through the raceway. The cable sheath must be ____________ and extend into the enclosure at least a _____________ in. The raceway must be _____________. When cable(s) are installed in raceways as mentioned above, what NEC Table and Chapter provide guidance on the cable fill require- ments for complete conduit and tubing systems, which this is to be considered. Table _______, Chapter _________.
Chapter27: Service-entrance Equipment
Section: Chapter Questions
Problem 17R
Related questions
Question
- As permitted, installing cables of entirely nonmetallic sheaths into the top of a surface-mounted enclosure through one or more nonflexible raceways, the raceways shall be not less than ________ and not more than __________ in length, provided they meet all of the following conditions:
- Nonmetallic-sheathed cable secured within __________ in. from where it emerges from the raceway.
- The raceway comes out of the top of the enclosure and making sure it does not penetrate a ___________ .
- A fitting is needed at each end of the raceway, and it must remain accessible after the install in order to protect against _____________.
- Raceways must be _____________ or ___________ to prevent access into the enclosure through the raceway.
- The cable sheath must be ____________ and extend into the enclosure at least a _____________ in.
- The raceway must be _____________.
- When cable(s) are installed in raceways as mentioned above, what NEC Table and Chapter provide guidance on the cable fill require- ments for complete conduit and tubing systems, which this is to be considered. Table _______, Chapter _________.
- Nonmetallic-sheathed cable secured within __________ in. from where it emerges from the raceway.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 3 steps
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT