An air conditioner on a summer day removes heat steadily from a house at a rate of 750 kJ/min while drawing electric power at a rate of 5.25 kW. Please answer the following. a. Create a schematic representation of the air conditioning system under consideration. b. Determine the COP of this air conditioner and the rate of heat transfer to the outside air. c. Now winter has come, and the owner decides to use the equipment as heat pump to warm the house. Because the house is not perfectly insulated, and the outside temperature is 0°C the estimated rate of heat transfer loss rate from the house to the surroundings is equal to 1200 kJ/min. Will the air conditioning unit operating as heat pump satisfy the required heating if the electrical power drawn is 5.25 kW? Explain how you arrived at the answer. d. If the heat pump would operate as a Carnot Heat Pump and the indoor temperature is 25°C while the outside temperature is 0°C, compute the COP.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 2RQ: The operating condition for the single compressor in a household refrigerator is the lowest box...
icon
Related questions
Question

An air conditioner on a summer day removes heat steadily from a house at a rate of 750 kJ/min while
drawing electric power at a rate of 5.25 kW. Please answer the following.
a. Create a schematic representation of the air conditioning system under consideration.
b. Determine the COP of this air conditioner and the rate of heat transfer to the outside air.
c. Now winter has come, and the owner decides to use the equipment as heat pump to warm the
house. Because the house is not perfectly insulated, and the outside temperature is 0°C the
estimated rate of heat transfer loss rate from the house to the surroundings is equal to 1200
kJ/min. Will the air conditioning unit operating as heat pump satisfy the required heating if the
electrical power drawn is 5.25 kW? Explain how you arrived at the answer.
d. If the heat pump would operate as a Carnot Heat Pump and the indoor temperature is 25°C
while the outside temperature is 0°C, compute the COP.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning