A medium-rise building with inductive loads has an average consumption of 40 kW and 26 KVAR. At the area where the building is located, the electric utility imposes a surcharge (or additional payment, in %) based on the power factor of the load. The utility uses the table below to determine the surcharge. Power factor Surcharge 90 to 100% None 88 to <90% 2% 85 to <88% 4% 80 to <85% 9% 75 to < 80% 16% 70 to < 75% 24% 65 to < 70% 34% 60 to < 65% 44% 55 to <60% 57% 50 to <55% 72% Less than 50% 80% The building occupants are planning to avoid the additional cost by installing a capacitor (to be connected in parallel with the building) for localized reactive power production. The target is to reduce the surcharge to 0%. a. What is the minimum KVAR the capacitor should produce to meet the target?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

pls write legibly for the solutions

A medium-rise building with inductive loads has an average consumption of 40 kW and 26
KVAR. At the area where the building is located, the electric utility imposes a surcharge (or
additional payment, in %) based on the power factor of the load. The utility uses the table below
to determine the surcharge.
Power factor
Surcharge
90 to 100%
None
88 to <90%
2%
85 to <88%
4%
80 to <85%
9%
75 to < 80%
16%
70 to < 75%
24%
65 to < 70%
34%
60 to < 65%
44%
55 to <60%
57%
50 to <55%
72%
Less than 50%
80%
The building occupants are planning to avoid the additional cost by installing a capacitor (to be
connected in parallel with the building) for localized reactive power production. The target is to
reduce the surcharge to 0%.
a. What is the minimum KVAR the capacitor should produce to meet the target?
Transcribed Image Text:A medium-rise building with inductive loads has an average consumption of 40 kW and 26 KVAR. At the area where the building is located, the electric utility imposes a surcharge (or additional payment, in %) based on the power factor of the load. The utility uses the table below to determine the surcharge. Power factor Surcharge 90 to 100% None 88 to <90% 2% 85 to <88% 4% 80 to <85% 9% 75 to < 80% 16% 70 to < 75% 24% 65 to < 70% 34% 60 to < 65% 44% 55 to <60% 57% 50 to <55% 72% Less than 50% 80% The building occupants are planning to avoid the additional cost by installing a capacitor (to be connected in parallel with the building) for localized reactive power production. The target is to reduce the surcharge to 0%. a. What is the minimum KVAR the capacitor should produce to meet the target?
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Magnetically Coupled Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,