A lossless coaxial cable transmission line has L = 200 uH/ft and C = 100 nF/ft. The inner diameter of the outer conductor is 3cm and the diameter of the inner conductor is 1cm. What is the dielectric constant of the insulator?
Q: What is the dispersion taking place in long transmission lines? State the condition to obtain…
A: In long transmission lines frequency dispersion takes place. In which transmission lines have…
Q: A 3-phase, 220 kV, 50 Hz transmission line consists of 1-2 cm radius conductors spaced 2 m at the…
A:
Q: Why is the Geometric Mean Distance (GMD) of two different conductors the same in a transmission line…
A: GMR stands for geometric mean radius which is also known as self GMD it is mean of the distance of…
Q: A 3 phase 140 kV line with 43.715 cm of distance separation between the conductor so that corona…
A: According to question: Let the radius of conductor = r. Air density factor is calculated as…
Q: A 15-km, 60Hz, single phase transmission line consists of two solid conductors, each having a…
A: Given data: The given loop length=15×103m Total inductance use formula L =15×103μπlogeDr+μi4π…
Q: A load with an impedance of 424.3045° N is connected to a 100 N lossless line. Using the Smith Chart…
A:
Q: A lossless transmission line has an inductance of 125 nH/m. Find the velocity factor for this line…
A:
Q: A transmission line is supported from two towers at heights of 40 m and 58 m above ground level, the…
A:
Q: .A 3-phase, 220 k 50Hz transmission line consists of 1.5 cm radius conductor spaced 2 metres apart…
A: According to the question we have calculate corona loss per km of the line.
Q: is desired to construct uniform transmission lines using polyethylene (εr = 2.25) as the dielectric…
A:
Q: 2. A 3-phase, 132 KV , 50 Hz, 100 Km, single circuit bundle conductor transmission line as shown in…
A:
Q: A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4…
A: Given, A single phase transmission line consists of two conductors. Radius of each conductor (r)=…
Q: Q4) A 3-phase, 400 kV, 50 Hz transmission line consists of 12.4 mm radius conductors spaced 3.5 m at…
A: The value of power loss due to corona is given by:- where f is the frequency, r is the radius and…
Q: A straight cylindrical interconnect line is 2 mm long and 200 um in diameter. What is the fastest…
A:
Q: In a lossless medium for which 7 = 607, µ, = 1, and H = -0.1 cos (wt - z) a, 0.5 sin (wt - z)a, A/m,…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: If the load connected to a lossless, 75-0 transmission line has a resistance of 100 0, calculate the…
A: (a) Given, Transmission line resistance (Zo)=75 ohm The transmission line connected to a load , R…
Q: A 3-phase, 440 kV transmission line consists of 2:5 cm radius conductor spaced 3 meters apart in…
A:
Q: A three phase 60HZ, 85kV transmission line consisting of 3 conductors are placed at the corners of a…
A: As per Bartleby guidelines we are allowed to solve only three subparts, please ask the rest again.
Q: TUTORIAL PROBLEMS 1. Estimate the corona loss for a three-phase, 110 kV, 50 Hz, 150 km long…
A: The Correct solution can be achieved as follows.
Q: he geometric mean radius of the conductor in a 380 kV, 120 km long transmission line 24 mm. The…
A: Given that Vline=380 KV Vph=3803=219.40KVL=120 Kmr=242=12 mmd=3.2mroughness factor m0=0.98b=725 mm…
Q: A loss less transmission line of length 3.125m with characteristic impedance 502, is operating on…
A: Note :- As per guidelines we are supposed to answer only three subparts at a time. So, I request you…
Q: In a lossless medium for which 7 = 607, µ, = 1, and H = -0.1 0.5 sin (wr - z)a, A/m, calculate e, w,…
A: The solution can be achieved as follows.
Q: A 3-phase, 220 kV, 50 Hz transmission line consists of 11.13 mm radius conductors spaced 6.0 m at…
A:
Q: The lossless network given below is excited with a microwave source having frequency f=4,8 GHz.…
A:
Q: Estimate the corona loss for a 3-phase, 110 kV, 50 Hz, 150-km-long transmission line consisting of…
A:
Q: A 10 km long, transmission-line has two parallel conductors placed 2 metres apart. The diameter of…
A: Given L =10 km D =1.4 cm P =2x83x10-8 Ω-mt
Q: The observed standing wave ratio on a 100 Ω lossless line is 8. If the first voltage maximum occurs…
A: Given Z0 = 100 ohm, s = 8, θτ-2βl=0θτ=2βlθτ=22πλ(0.3λ)θτ=4πλ(0.3λ)θτ=216°
Q: Q2. A 3-phase, 132 KV, 50 Hz , 100 Km, single circuit bundle conductor transmission line as shown in…
A: In this question, find the inductance of the transmission line as per given system. We know…
Q: A 376-2 lossless air transmission line is connected to a complex load composed of a 749-2 resistor…
A:
Q: A lossless 500 transmission line was terminated with a load of = 17.7 + j11.80. The length of the…
A: we need to calculate the reflection coefficient at the entrance.
Q: Question#01: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.9 Farad/meter, and 8…
A:
Q: A 132 KV line with 2 cm diameter conductors is built so that corona takes place if the line voltage…
A:
Q: A 50Ω lossless transmission line is terminated in a load (50+j100) Ω. Using a smith chart, determine…
A: Given, Impedance, Z0=50ΩLoad Impedance, ZL =(50+j100)Ω
Q: In a lossless medium for which η = 30 π, μr = 1, and H = -0.1 cos (ωt-z)ax +0.5 cos (ωt-z)ay A/m,…
A: Given data, η=30πμr=1H=-0.1cosωt-zax+0.5cosωt-zay A/m
Q: 9. In air, a lossless transmission line of length 50 cm with L=10µH/m, 40PF/m is operated at 25 MHz.…
A:
Q: In air, a lossless transmission line of length 50 cm with 10µH/m, C = 40PF/m is operated at 25 MHz.…
A: Given a lossless transmission line having, Length, l = 50 cm Inductance, L=10 μHm Capacitance, C=40…
Q: Q20. Choose the type of cable used to for short distance subscriber loop. Justify why this cable is…
A:
Q: Q3) In a lossless medium for which 7 = 60t, H, = 1, and H = -0.1 cos(@t – z)ax + 0.5 sin(wt – z)a,…
A: Here i have solved it.
Q: A microstrip line is composed of zero thickness copper conductors on a substrate having εr = 8.4,…
A: Given, εr=8.4W=0.5 mmh=1.5 mmfrequency of operation= 6 GHz Wh=0.5 mm1.5 mmWh=0.3333Wh=0.3333<1
Q: A 115 kv line has a horizontal configuration. The distance between adjacent conductors is 9ft. What…
A: The solution can be achieved as follows.
Q: Q3: A lossy transmission line has a complex propagation constant of y 0.012+5.8 (/m). If the voltage…
A: Given,Y=0.012+j5.8 /mV0=12Voltz=d=12 mWe know that,V=V0e-αz Equation 1where α is…
Q: QUESTION.2. A lossless air transmission line with Z, = 50 N is connected to a complex load composed…
A:
Q: A 30-m-long lossless transmission line with Z, = 50 N operating at 2 MHz is termina with a load Z, =…
A: Reflection coefficients determine how much wave is is reflected at discontinuity of medium.It is…
Q: Q4) A 3-phase, 400 kV, 50 Hz transmission line consists of 12.4 mm radius conductors spaced 3 m at…
A:
Q: In a lossless medium for which 7 = 607, , = 1. and H= -0.1 cos (ot - 2) a, + 0.5 sin (wt - z)a, A/m,…
A: ELECTRIC FIELD: The region around charged particles into which when another charge is brought in it…
Q: Question 3 (a) A lossless transmission line with Z. line is terminated with a load impedance, Z, =…
A:
Q: c) Figure 3 depicts a lengthwise cross-section of a coaxial transmission line, indicating the…
A:
Q: Q4] Draw the phaser diagram of sending and receiving voltages and currents across a long…
A: Long transmission line-It is defined as a transmission line with a distance of more than 250km.…
Q: (a) A lossless transmission line with Z, line is terminated with a load impedance, Zį = 100 + j100…
A:
A lossless coaxial cable transmission line has L = 200 uH/ft and C = 100 nF/ft. The inner diameter of the outer conductor is 3cm and the diameter of the inner conductor is 1cm. What is the dielectric constant of the insulator?
Step by step
Solved in 2 steps with 3 images
- Determine the GMR of each of the unconventional stranded conductors shown in Figure 4.30. All strands have the same radius r.Assume that a single-conductor belted cable has a conductor diameterof 0.681 in., inside diameter of sheath of 1.7025 in., and a length of8000 ft. The cable is to be operated at 12.47 kV. The dielectricconstant is 4.5, and the power factor of the dielectric at a ratedfrequency and temperature is 0.05. Calculate the following:(a) Capacitance of cable.(b) Charging current.(c) Dielectric loss of cable.(d) Equivalent resistance of insulation.5. A coaxial cable, having an inner diameter of 0.025mm and using an insulator with dielectric constant of 2.56, is to have a characteristic impedance of 2000 2. What must be the outer conductor diameter?
- A single core lead covered cable is to be designed for 68 kV(peak value) toearth. Its conductor diameter is 2 cm and its three insulating materials havepermittivities of 5, 4 and 3 respectively with the corresponding maximumsafe working stress of 38 kV/cm (r.m.s), 26 kV/cm (r.m.s) and 20 kV/cm(r.m.s) respectively. Find the minimum diameter of lead sheath.Example 4.3 The line in Example 4.2 is replaced by two ACSR 636, 000-cmil, 24/7 Rook conductors which have the same total cross-sectional area of aluminum as one Bittern conductor. The line spacing as measured from the center of the bundle is the same as before and is shown in Figure 4.20. a b 0,0 0,0 0,0 +18"+ -D12 = 35'- -D23 = 35' -D13 = 70- 35'A double-circuit its capacitance to neutral per mile. line is shown below. The conductor radius is 0.0452 ft. Determine 16' 16' a b 22' c' b' a'
- Q2: A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. (1) The capacitance in µF/km without effect of ground? (2) The capacitance in µF/km with effect of ground?A single core cable is to be used for 66 kV to earth. Its conductor diameter is 2 cm and its three insulating materials have permittivity 5, 4 and 3 respectively. The corresponding safe maximum stresses are 38 kV/cm, 26 kV/cm and 20 kV/cm, respectively. Find the minimum diameter of the sheath.A three phase, 33 KV, underground cable system, consider a single core of conductor radius 0.8 cm diameter and lead sheath of 2.3 cm. The core and lead sheath have been separated by two intersheaths with radius 1.3 cm and 1.8 cm. Draw the cable core, dielectric and intersheath layers showing the thickness of each layer, then determine the voltages on the both intersheaths. Suppose the maximum stress on the layers are the same. Please i need it know please
- A three phase, 11 KV, underground cable system, consider a single core of conductor radius 0.5 cm diameter and lead sheath of 1.25 cm. The core and lead sheath have been separated by two intersheaths with radius 0.75 cm and 1 cm. Draw the cable core, dielectric and intersheath layers showing the thickness of each layer, then determine the voltages on the both intersheaths. Suppose the maximum stress on the layers are the same.A 115 kv line has a horizontal configuration. The distance between adjacent conductors is 9ft. What is the geometric mean distance of the line?The conductor shown in the figure below is composed of five strands. The diameter of each strand is 2.5 mm. Find the GMR (Geometric mean radius) of the conductor.