A gas stream containing acetone in air flows from a solvent recovery unit at a rate of 142 L/s at 150°C and 1.3 atm. The stream flows into a condenser which condenses most of the acetone, and the liquid and gas outlet streams are in equilibrium at -18°C and 5.0 atm. Shaft work is delivered to the system at a rate of 25.2 kW to achieve the compression from 1.3 atm to 5.0 atm. To determine the condenser feed stream composition, a 3.00-liter sample of the gas is taken and cooled to a temperature at which essentially all the acetone in the sample is recovered as a liquid. The liquid is poured into an empty flask with a mass of 4.017g. The flask containing the liquid acetone is weighed and found to have a mass of 4.973 g. Q(KW) W-25.2 kW 142 L/s, 150°C, 1.3 atm acetone(v), air CONDENSER 3-liter sample Condense and weigh acetone Gas at -18°C, 5 atm acetone(v), air Acetone(1) at -18°C, 5 atm (a) Carry out a degree-of-freedom analysis to show that enough information is available to determine the compositions of all streams and the required heat transfer rate. (b) Write out a complete set of equations for the molar flow rates of all streams, the mole fractions of acetone in the feed and product gas streams, and the rate (kW) at which heat must be removed in the condenser. Do no calculations.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
A gas stream containing acetone in air flows from a solvent recovery unit at a rate of 142 L/s at 150°C and
1.3 atm. The stream flows into a condenser which condenses most of the acetone, and the liquid and gas
outlet streams are in equilibrium at -18°C and 5.0 atm. Shaft work is delivered to the system at a rate of
25.2 kW to achieve the compression from 1.3 atm to 5.0 atm. To determine the condenser feed stream
composition, a 3.00-liter sample of the gas is taken and cooled to a temperature at which essentially all
the acetone in the sample is recovered as a liquid. The liquid is poured into an empty flask with a mass of
4.017g. The flask containing the liquid acetone is weighed and found to have a mass of 4.973 g.
O(kW) W = 25.2 kW
142 L/s, 150°C, 1.3 atm
acetone(v), air
CONDENSER
3-liter sample
Condense and weigh acetone
Gas at-18°C, 5 atm
acetone(v), air
Acetone(1) at -18°C, 5 atm
(a) Carry out a degree-of-freedom analysis to show that enough information is available to determine
the compositions of all streams and the required heat transfer rate.
(b) Write out a complete set of equations for the molar flow rates of all streams, the mole fractions of
acetone in the feed and product gas streams, and the rate (kW) at which heat must be removed in
the condenser. Do no calculations.
Transcribed Image Text:A gas stream containing acetone in air flows from a solvent recovery unit at a rate of 142 L/s at 150°C and 1.3 atm. The stream flows into a condenser which condenses most of the acetone, and the liquid and gas outlet streams are in equilibrium at -18°C and 5.0 atm. Shaft work is delivered to the system at a rate of 25.2 kW to achieve the compression from 1.3 atm to 5.0 atm. To determine the condenser feed stream composition, a 3.00-liter sample of the gas is taken and cooled to a temperature at which essentially all the acetone in the sample is recovered as a liquid. The liquid is poured into an empty flask with a mass of 4.017g. The flask containing the liquid acetone is weighed and found to have a mass of 4.973 g. O(kW) W = 25.2 kW 142 L/s, 150°C, 1.3 atm acetone(v), air CONDENSER 3-liter sample Condense and weigh acetone Gas at-18°C, 5 atm acetone(v), air Acetone(1) at -18°C, 5 atm (a) Carry out a degree-of-freedom analysis to show that enough information is available to determine the compositions of all streams and the required heat transfer rate. (b) Write out a complete set of equations for the molar flow rates of all streams, the mole fractions of acetone in the feed and product gas streams, and the rate (kW) at which heat must be removed in the condenser. Do no calculations.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 7 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The