A DO shunt generator delivers 45 A at a terminal voltage of 220 V. The armature and the shunt field resistances are 0.01 2 and 44N respectively. The stray losses are 375 W. What is percentage efficiency of the DC generator

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter32: Three-phase Motors
Section: Chapter Questions
Problem 8RQ
icon
Related questions
Question
100%
A DC shunt generator delivers 45 A at a terminal
voltage of 220 V. The armature and the shunt field
resistances are 0.01 2 and 44N respectively. The stray
losses are 375 W. What is percentage efficiency of the DC
generator
Transcribed Image Text:A DC shunt generator delivers 45 A at a terminal voltage of 220 V. The armature and the shunt field resistances are 0.01 2 and 44N respectively. The stray losses are 375 W. What is percentage efficiency of the DC generator
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer