A 110 V, 60 Hz, 6 - pole single phase induction motor 173 hp has the following equivalent circuit impedances: RI = 1.52 ohm, R2 = 3.13 ohm and x1 =2.10 ohm, x2 =1.56 ohm. Xm=58.2 ohm, The Friction, windage and stry losses =16W, the core loss = 35 W, For a slip of 0.05, calculation (a) input current, (b) power factor, (c) developed power, |(d) output power, (e) speed (f) in put power (g) air gab power (h) T ind (i) T load 6) efficiency.
A 110 V, 60 Hz, 6 - pole single phase induction motor 173 hp has the following equivalent circuit impedances: RI = 1.52 ohm, R2 = 3.13 ohm and x1 =2.10 ohm, x2 =1.56 ohm. Xm=58.2 ohm, The Friction, windage and stry losses =16W, the core loss = 35 W, For a slip of 0.05, calculation (a) input current, (b) power factor, (c) developed power, |(d) output power, (e) speed (f) in put power (g) air gab power (h) T ind (i) T load 6) efficiency.