4. An Open-Wye/Open-Delta transformer, as shown in Figure, is formed by two identical single-phase transformers. The primary line-to-line voltage is 12.47 kV, and the secondary line-to-line voltage is 208 V. Take
Q: True or False? Consider a 3 phase transformer with same line to line voltage ratio. The delta…
A: Delta to Delta transformer: The primary phase current is,I1=13IL1The secondary phase currennt…
Q: Consider Figure 1 of the text. For an ideal phase-shifting transformer, the impedance is unchanged…
A: Referring to the given hints, the impedance of the secondary side seen from the primary side:
Q: If the open circuit voltage is 239V and the full load voltage is 205V, then the percentage…
A: Voltage Regulation is nothing but ratio of drop in voltage from no load to full load to full load…
Q: If the open circuit voltage is 225V and the full load voltage is 200V, then the percentage…
A:
Q: For an ideal 2-winding transformer, an impedance Z2 connected across winding 2 (secondary) is…
A: For a 1-phase transformer, the basic relation is given as:
Q: Describe the On-load and No-load in transformers
A: On-load in transformer Current flows through the secondary winding and out to the load when an…
Q: Example 1: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results:…
A:
Q: where a dashpot mechanism is employed in a constatant-current transformer, it is used as a…
A:
Q: Consider the following short circuit transformer as shown in figure below which operate at: the…
A: The solution is given below
Q: "Under saturated core condition, transformer become a source of harmonics" True False
A: In this question , we will write about harmonics in transformer..
Q: These transformers normally mounted on power poles or installed inside a large building near…
A: 1) Transformer is an electrical machine which step up step down the voltage without change in…
Q: The diagram for a single phase 60 MVA transformer is given below. Convert it to a Step-down…
A: Design the step down autotransformer Single phase transformer have 60MVA 50/100kV Find the all…
Q: Derive physically the reason of the phase shift in three phase transformer and show the phase shift…
A: The given problem can be laid down into parts. Firstly, the reason of the phase shift in the three…
Q: Using the parameters from the Typical Transformer Values Sheet for a 12.4kV/600V, 100 kVA…
A:
Q: 1. The RMS value of induced emf in the primary N1 winding is E1 =; E2 = 2. In ideal transformer on…
A:
Q: a) An ideal single-phase two-winding transformer with turns ratio a, = N1/N2 is con nected with a…
A: A. The basic relation for a single- phase two winding transformer…
Q: Questions:- 1. What happen when the two transformers are operated in parallel having un equal turn's…
A: According to the bartleby's guidelines we have to solve only one question posted by students so…
Q: If the open circuit voltage is 225V and the full load voltage is 214V, then the percentage…
A: Percentage regulation is given by R R = (VOC - VFL ) / VFL VOC = Open circuit voltage VFL =…
Q: A single-phase l0-kVA, 480/1120 -V transformer is to be used as an auto transformer tying a 600V…
A:
Q: Data from short-circuit and open-circuit tests of a 25-kVA, 6900-230 V, 60 Hz transformer are given…
A:
Q: 3.1 (a) An ideal single-phase two-winding transformer with turns ratio a, = N1/N2 is con- nected…
A:
Q: A generator (480 V, 10 kVA) is connected to an ideal step-up transformer (1:20), and a transmission…
A: Most of human energy requirement is meet by generating electrical energy. Once electrical energy is…
Q: 60 KVA, 415-220 V, 50 Hz transformer I.(exciting current)=2% of the rated current current at 0.75…
A:
Q: Transformer rated powers and relative short-circuit rates in a step-down transformer station are…
A: For the electrical design of the electrical substation, Short circuit MVA and Short circuit current…
Q: why is there preferable use isolating transformers with cascade transformer unit , if the power…
A: Autotransformers are also known as Isolation Transformer. This is due to the fact that their…
Q: 4. Write a conclusion for the experiment, stating the role of core loss.component and magnetizing…
A:
Q: A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent…
A:
Q: Hw2.1-3: Derive the following: ing. The shift angle of line voltages for delta/star transformer…
A: In a delta-Star connected transformer, the primary is connected in delta and the secondary is…
Q: PROBLEM A 3300V/440V, single-phase transformer takes a no-load current of 0.8A and the iron loss is…
A:
Q: Q1: What is the influence of transformer connections in single-phase transformers connected for 3-…
A: According to the Bartleby guidelines “Since you have asked multiple question, we will solve the…
Q: For an ideal 2-winding transformer, the armpere-turns of the primary winding, N1/1, is equal to the…
A: For the magnetic circuit, the magneto-motive force is given as:
Q: 3. A 10 kVA, single-phase transformer has a turns ratio of 15:1 and is supplied from a 2,0 kV…
A: Single phase transformer 10KVA , turn ratio 15:1 Primary side voltage 2KV Find the secondary…
Q: Determine the efficiency of three-phase 400 kVA, 11kV/ 380 V transformer at over-loading condition…
A:
Q: Quiz2: We wish to connect a 6 kVA, 120/240 V transformer as an autotransformer to a 120 V source to…
A:
Q: The following test data were obtained from short-circuit and open-circuit tests of a 50-kVA,…
A: Given data Apparent power is S = 50 kVA Voltage is V = 600 V frequency is f = 60 Hz a) Calculating…
Q: A two-winding transformer rated at 100 kVA, is connected as an autotransformer to provide 10kV from…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: Solve for the efficiency at three-eight load at 0.85 power factor of a 10-kVA single phase…
A: As per our guidelines, we are supposed to answer only one question. Kindly repost the question as a…
Q: As given in the figure, an ideal transformer with a 2: 1 winding ratio is fed from a 240 Volt source…
A:
Q: A 37.5-kVA, 6900-230-V, 60-Hz, single-phase transformer is operating in the step-down mode at rated…
A: a) Given data Apparent power is S = 37.5 KVA Low side voltage is VLS = 230 V Frequency is f = 60 Hz…
Q: Justify if in a Yy transformer (without neutral wire on the supply side) there are homopolar…
A: Here it is mentioned that in a three Yy transformer there are homopolar components of fluxes,…
Q: A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent…
A:
Q: a) Discuss two (2) advantages and disadvantages of using three single-phase transformers instead of…
A: NOTE: Since you have asked multiple questions, we will solve the first question for you. If you want…
Q: Consider a current transformer with a turns ratio of 400: 4, a secondary leakage impedance of (0.08…
A: In the given circuit diagram Turn ratio = 400 : 4 secondary leakage impedance is (0.08 + j0.8)…
Q: A single-phase transformer, working at unity power factor has an efficiency of 90 % at both…
A:
Q: A conventional phase transformer given in the figure will be connected as an autotransformer in two…
A: A conventional phase transformer given After convert into auto transformer power rating 1.…
Q: 12.a. Comparing the transformer cores of core-form and shell-form transformers shows that the a.…
A: Solution of question (12.a): Four options are given, we need to choose the correct option. The…
Q: A three-phase Y-Y transformer has specifications of 25 MVA, 15/200 kV and an equivalent series…
A: The solution is given below
Q: A, determine V½ l, Z, and the impedance Z',, which is the value of Z, referred to the primary side…
A: Given: N1=1000N2=250V1=1000∠0°I1=5∠30° The relation between voltage and the turns of the transformer…
Q: A 10 MVA three phase load is to be served by a three phase transformer at a line voltage of 13.8 kV.…
A: Transformer is the static device it is used to transfer the electrical power from one terminal to…
Trending now
This is a popular solution!
Step by step
Solved in 7 steps with 9 images
- An ideal transformer has no real or reactive power loss. (a) True (b) FalseA 23/230-kV step-up transformer feeds a three-phase transmission line, which in turn supplies a 150-MVA,0.8 lagging power factor load through a step-down 230/23-kV transformer. The impedance of the line and transformers at 230kVis18+j60. Determine the tap setting for each transformer to maintain the voltage at the load at 23 kV.Consider an ideal transformer with N1=3000andN2=1000 turns. Let winding 1 be connected to a source whose voltage is e1(t)=100(1| t |)volts for 1t1ande1(t)=0 for | t |1 second. A2- farad capacitor is connected across winding 2. Sketch e1(t),e2(t),i1(t),andi2(t) versus time t.
- (a) An ideal single-phase two-winding transformer with turns ratio at=N1/N2 is connected with a series impedance Z2 across winding 2. If one wants to replace Z2, with a series impedance Z1 across winding 1 and keep the terminal behavior of the two circuits to be identical, find Z1 in terms of Z2. (b) Would the above result be true if instead of a series impedance there is a shunt impedance? (c) Can one refer a ladder network on the secondary (2) side to the primary (1) side simply by multiplying every impedance byat2 ?For a short-circuit test on a 2-winding transformer, with one winding shorted, can you apply the rated voltage on the other winding? (a) Yes (b) NoIn per-unit equivalent circuits of practical three-phase transformers, under balanced thr-phase operation, in which of the following connect ions would a phase-shifting transformer come up? (a) Y-Y (b) Y- (c) -
- Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage windings are connected in Y. (a) For the low-voltage side, connect the windings in , place the polarity marks, and label the terminals a, b, and c in accordance with the American standard. (b) Relabel the terminals a, b, and c such that VAN is 90 out of phase with Va for positive sequence.A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a balanced load of three 1, Y-connected resistors. Choosing a base of 90MVA,66kV for the high-voltage side of the three-phase transformer. spify the base for the low-voltage side. Compute the per-unit resistance of the load on the base for the low-voltage side. Also, determine the load resistance in ohms referred to the high-voltage side and the per-unit value on the chosen base.For an ideal 2-winding transformer, an impedance Z2 connected across winding 2 (secondary) is referred to winding 1 (primary) by multiplying Z2 by (a) The turns ratio (N1/N2) (b) The square of the turns ratio (N1/N2)2 (c) The cubed turns ratio (N1/N2)3
- The ratings of a three-phase three-winding transformer are Primary(1): Y connected 66kV,15MVA Secondary (2): Y connected, 13.2kV,10MVA Tertiary (3): A connected, 2.3kV,5MVA Neglecting winding resistances and exciting current, the per-unit leakage reactances are X12=0.08 on a 15-MVA,66-kV base X13=0.10 on a 15-MVA,66-kV base X23=0.09 on a 10-MVA,13.2-kV base (a) Determine the per-unit reactances X1,X2,X3 of the equivalent circuit on a 15-MVA,66-kV base at the primary terminals. (b) Purely resistive loads of 7.5 MW at 13.2 kV and 5 MW at 2.3kV are connected to the secondary and tertiary sides of the transformer, respectively. Draw the per- unit impedance diagram, showing the per-unit impedances on a 15-MVA,66-kV base at the primary terminals.A single-phase, 50-kVA,2400/240-V,60-Hz distribution transformer has the following parameters: Resistance of the 2400-V winding: R1=0.75 Resistance of the 240-V winding: R2=0.0075 Leakage reactance of the 2400-V winding: X1=1.0 Leakage reactance of the 240-V winding: X2=0.01 Exciting admittance on the 240-V side =0.003j0.02S (a) Draw the equivalent circuit referred to the high-voltage side of the transformer. (b) Draw the equivalent circuit referred to the low-voltage side of the transformer. Show the numerical values of impedances on the equivalent circuits.ََQ/ 400/200 V, single-phase transformer is supplying a load of 50A at a power factor of 0.866 lagging. The no-load current is 2A at 0.208 p.f. lagging. .. Find The primary current is ...... A * The primary power factor is ........ lagging *