Based on the materials of the course, building loads for which an HVAC system must compensale include all of the following except Select one O a Ventilation toads O b Infitration toads O c Sensible load Od Transferrable loads
Q: Parts of Septic tank
A: A home septic tank system consists of underground storage and treatment of wastewater in tanks made…
Q: . Determine if what type of ventilation to be use (negative or positive pressure) 2. Determine the…
A:
Q: Environmental Engineering The air quality standard for ozone (O3) is 80 ppbv. Express that standard…
A: The air quality standard for ozone is 80 ppbv.The temperate (T) is 25ºC.Convert the unit of…
Q: It is generally desirable to provide mechanical ventilation in all rooms of a building which are…
A: It is generally desireable to provide mechanical ventilation in all rooms of a building which are…
Q: What is the size in feet of the grille needed to pass 180cubic feet per meter at 60 feet per minute…
A: To determine the size of grill which will allow for a given volumetric flow rate for given flow…
Q: Very close control of the conditions in the conditioned space can be achieved by adopting all-air…
A: Very close control of the conditions in the conditioned space can be achieved by adopting all-air…
Q: 2. At 1:00 pm, a thermometer reading 90°F is taken outside where the air temperature is 15°F. At…
A: Given data, Room temperature T0 = 90oF Outside temperature Ts = 15oF
Q: A water initially contains 140 L of water. Now equal rates of cold and hot water enter the tank for…
A:
Q: A metallic column is covered through 1 in. Thick (25.4 mm) spray implemented cementitious cloth. The…
A:
Q: A well-mixed, insulated water storage tank is to be maintained at internal temperature 60°C. The…
A:
Q: Parker County Community College (PCCC) is trying to determine whether to use no insulation or to use…
A: The present worth is calculated as, Maximize PW=∑t=0nAjt1+i-t .... (1) The annual heat…
Q: Q.3: Building requires to maintain different temperature settings. What are most common cooling…
A: Building cooling systems are in high demand in tropical countries. Especially where the high…
Q: Calculate the AQI and give a description of air that contains 5 ppm CO (8-hour average), 300 pg/m3…
A: AQI : AQI means Air Quality Index which is a measurement of various pollutants that are present in…
Q: 1. Rolling 2. Stages of Heat Treatment
A: Rolling Rolling is one of the most important and the widely used metal forming process because of…
Q: A well insulated room with a refrigerator running and door open, the air tem-perature in the room…
A:
Q: State the theoretical principle on which each of the following air pollution control devices…
A: The theoretical principle on which following air pollution control devices operate. 1. absorption…
Q: Calculate the fan power if the average pressure drop m 0.6 in, H2O, and the fan/motor efficiency is…
A: The given data is shown below: Pressure drop=0.6 in. H2OFan efficiency=70%Discharge=800,000…
Q: What are the main disadvantages of using a heat exchanger to cool the exhaust gases?
A: The heat exchanger cools the exhaust gas by recovering the heat energy of reciprocating diesel, gas…
Q: Discuss the systems and equipment available for cooling systems in large buildings.
A: It can be necessary to provide cooling to buildings during warm weather or where there are…
Q: A cold-storage warehouse is to be constructed of a number of individual rooms that are maintained at…
A:
Q: The purpose of heat treatment
A: Heat Treatment : Heat treatment is a collection of manufacturing, thermal and metalworking processes…
Q: Civil Engineering Consider two other houses with 200 [m?] of foundation area and 1000 [m'] volume.…
A: Steady concentration: When a chemical is administered constantly or frequently, the amount soaked up…
Q: Which of the following is not a method for stopping or impeding air leaks in a building? Installing…
A: Air leakage happens because of many reason such as openings in wall or cracks etc. The air enters…
Q: write the limitations of revers osmosis water treatment Techonolgy
A:
Q: Determine the required FRP duct diameter assuming a duct velocity (Uduct) of 2,000 ft/min, and an…
A: Given: The duct velocity is 2000 ft/min. The actual air emission rate is 15300 ft3/min.
Q: If the air quality standard for CO is given as 9.0 ppmv, express this standard as percent by volume…
A: Solution: We know that, 1 ppmv=1 part of pollutant106 parts of…
Q: A well-mixed, insulated water storage tank is to be maintained at internal temperature 60°C. The…
A:
Q: B/ heat exchanger in vapor compression system is necessary for two reasons , list them?
A: A heat exchanger transfer heat between 2 or more fluids. They are used in both cooling and heating…
Q: The tubes going to and from an air-conditioning condensing unit must passthrough a wall. The tubes…
A: Schematic diagram of the given problem:
Q: latrine for a family of eight. The family uses water for anal cleansing. The groundwater table is…
A: Given:- family mmebers=eight groundwater table=2.0m below ground surface To find:- design VIP…
Q: A room's sensible space load is from occupants and infiltration, but excluding intentional…
A:
Q: Air-conditioning units come in sizes of whole and half tons. A 1-ton airconditioningunit will cool a…
A: Given:- The size of the air-conditioning unit needed for 1100 sq ft = 1-ton To determine:- The…
Q: 10. In a building, to provide ultimate comfort to occupants can be used. А. О АС В. О HVAC C.…
A: In a building , to provide ultimate comfort to occupants can be used
Q: 10. In a building, to provide ultimate comfort to occupants can be used. А. О АС B. O HVAC C. O…
A: In a building, to provide ultimate comfort to occupants ________ can be used.a) ACb) HVACc)…
Q: Type of Heat Treatment.
A: Heat treatment is the procedure of heating metal without allowing it to reach its molten, or…
Q: A well-mixed, insulated water storage tank is to be maintained at internal temperature 60°C. The…
A: For any material, it's insulation capacity is defined by thermal resistance value which can be…
Q: ductwork systems
A: HVAC ductwork systems Here HVAC stands for Heating , Ventilation and Air conditioning
Q: Central air conditioning system is the main mechanical ventilation system that used in most of the…
A: Introduction : Air is cooled in a central place and transferred to and from rooms using one or more…
Q: Explain the HVAC system with the most suitable energy medium for usage in Architectural constraints…
A: Schematic diagram of the basic working of HVAC system:
Q: A flow of 125 gpm of chilled water at 45°F is to be transported from a chiller to a set of cooling…
A: Given data - Flow = 125 gpm Temperature = 45°F To find - Chilled water velocity in ft/s
Q: If (Qr/Q=120 percent of discharge), effluent BOD concentration=80ppm, volume of filter =825m3 ,…
A: Given QrQ=120% of discharge BOD concentration=80ppm volume of filter, V =825m3 Discharge , Q=50L/sec
Q: We need to obligatorily have ventilation i
A: To find : Whether the statement is true or false.
Q: Drain, Waste, and Vent System 1. Major components in a DWV sgstem. 2. Different types of piping…
A:
Q: Which statement is TRUE about displaceme ventilation in UFAD systems? air from the floor is prone to…
A: In UFAD, mixing is enhanced resulting in even air temperature.
Q: A flow of 125 gpm of chilled water at 45°F is to be transported from a chiller to a set of cooling…
A:
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- Volume of aeration tank.Refer to the attached plan and section to answer the succeeding questions 12mm THK. SLAB COVER WITH 10mmo RSB. SPACED E EVERY 200mm 0.C. B.W. 3000 1200 600 600 150 INLET p MANHO MANHOLE 150 16mmo RSB AT EVERY CORNER AND CHB JOINTS. PLAN 12mmo BAR LIFTING HANDLE 12mm THK. SLAB COVER WITH 12mmo RSB, SPACED EVERY 250mm O.C., B.W. 3000 1200 600 600 E नि्॥ 120 300mm. AIR SPACE INLET WATER LEVEL WATER LEVEL WATER LEVEL OUTLET JO PVC PPE AND FITTINGS DIGESTIVE LEACHING CHAMBER LEACHING CHAMBER CHAMBER USE 5 CHB WITH 10mme VERTICAL BARS SPACED 400mm AND HORRONTAL BARS O EVERY 3 LAYERS. 1:10SLOPE 150 1Smm THK. SLAB ON FILL WITH 12mmo RSB. SPACED E EVERY 250mm O.C., B.W. How thick is the Required plastering on the Septic tank walls from the given drawings O 1" each face O 1/2" each face O 1/4" each face O No Plastor reuirod 2070 000 000L 150Explain why an air barrier is called an air-weather barrier. Explain the difference between surface condensation and concealed condensation. Explain in which situations these two types of condensation would occur and why. Explain why an air barrier should be vapor permeable.
- discuss the materials requirement as per Indian standards for RCC water tank. considering , leakage , low permeability and durability.Question 5 Which statement about electrical conduction in wood is FALSE? O a. Electrical conduction increases very rapidly with increasing wood moisture content. O b. Electrical conduction is generally the same regardless of wood species. O C. Electrical conduction is greatest in the longitudinal direction of wood. Od. Electrical conduction increases with increased wood temperature.What are the three operational considerations that govern the design and manufacture of heat pipes?
- Industrial representatives claim that the ambient air quality standard for SO, is so low that one exceeds it if one strikes a simple wooden match in a modest-sized room. Is this true? (a) Calculate the concentration expected for striking such a match in a room that is 15' x 15' x 8'. A typical 2-inch wooden match contains, approximately, 2.5 mg of S. (b) Compare the resulting concentration to the annual average SO, ambient air quality standard.The insulation to be used in a certain slot is as follows: fish paper 3/64 inch, Tufflex 3/32 inch, varniches cambric 3/64 inch, and top stick 1/8 inch. What is the total thickness of the insulation?Parts of Septic tank