A Barangay power station supplies 60KW to a load over 2500 ft, 100mm squared, two conductor copper feeders, the resistance of which is 0.078 ohm per 1000ft. The bus bar voltage is maintained constant at 600V. Determine the maximum power which can be transmitted.
Q: ower electronics relate to the control and flow of an electrical energy. but why power electronic is…
A: Modern systems get their blood from power electronics.Distributed generation or DG in the smart grid…
Q: 4. Regional Maritime University (RMU) campus has 200 classrooms and 400 faculty offices. The…
A: Given: Total classroom is 200 Total faculty room is 400 Fluorescent tubes in each classroom is 12…
Q: Determine the size of PV modules, inverter, battery and solar charge controller of a PV systems…
A: Here, we have given some information about devices present in a house. We will first calculate the…
Q: A three phase transmission line consisting of 3 conductors placed in the at the corners of a…
A: The capacitance of 3 phase transmission line per phase is given by Cph=2πεologed1d2d33r Cph is…
Q: Q1. A 3 core, 3-phase belted cable tested for capacitance between a pair of cores on single phase,…
A:
Q: Develop an expression for voltage and current traveling on a transmission line assuming all its…
A: we need to develop an expression for voltage and current traveling on a transmission line assuming…
Q: 2- Petermine the Veilue of Rs which is requireed to conneel it with the moving Cail to obtain (5v,…
A:
Q: A RC network supplied with 40V battery is shown in the following figure: a)Find the mathematical…
A: The RC network is shown below,
Q: A rectangular aluminum bus bar is 0.9m long, 0.15 m wide, 0.013m (1.3cm) thick. If the current in…
A:
Q: D: A 3 phas e, 50 HZ Transmission line (100km) Long delivers 50 MUA, o.8pf Lagging and 110kv the…
A:
Q: Q4: A: A string of 3 insulators and the ratio of Ce/C = 0.15, if the string is connected to 3-0 line…
A:
Q: A communication system uses 20 km of fiber that has a –3.1 dB/km loss characteristic. Find the…
A: Fiber optic loss is typically expressed in terms of decibels (dB) and can be calculated as:…
Q: A spacecraft that operates in a circular 425-km low-Earth orbit has a battery with 4 kW load at 28…
A: (a) Given parameters are as follows Load power PL=4kW=4×103 Watt Load voltage VL=28 V Individual…
Q: The outer radius of a coaxial cylindrical electrode system is given as 38 cm. The system is the most…
A: It is given that the outer radius of a coaxial cylindrical electrode system is 32 cm. For the…
Q: f. oooo M x(1) f(n)
A: In mechanical network interconnection of mechanical network along a circuit diagram. In mechanical…
Q: A 110 kV, single core coaxial, XLPE insulated power cable delivering power at 50 Hz, has a…
A: Given values are - VoltageV=110kVf=50HzCapacitanceC=125nFkmDielectric loss tangent tanδ=2×10-4
Q: A 3-phase, 50 Hz, 132 kV overhead line has conductors placed in a horizontal plane 4 m apart.…
A:
Q: 2. The electric power which a transmission line can transmit is proportional to the product of its…
A:
Q: A transmission aluminum cable 5mm in diameter. Find the 50 degree Celsius AC resistance per km of…
A:
Q: Q4. A Transmission Line has a span of 250 meters between two level supports. The conductor has a…
A: Given in the question: Span length, l = 250 meters Cross sectional area of the conductors, A = 1.29…
Q: What is the maximum length in km for a 1-phase transmission line having copper conductor of 0-775…
A: We have been asked to find the maximum length in km for 1-phase transmission line having, Copper…
Q: A single phase transmission line having copper conductor of 0.775 cm2 cross section over which 300…
A: Cross sectional area= 0.775cm2
Q: For a naturally flowing oil well at 300 m3/d, with Pwf "perf depth = 10000 kpa and a fluid gradient…
A: Production Index formula- PI=QoPs-Pwfwhere,Q=oil flow ratePs=static pressure in the wellPwf=bottom…
Q: The puncture resistance of the insulator used in an AA cable with a conductor cross section of 150…
A: Given:Emax=200 kV/cm=200×103×102Emax=200×105 V/mArea of conductor, A=150 mm2…
Q: QI. A transmission line has a conductor weight of 1200 kg/km and stress of 1110 kg. The sag was 9m.…
A: For a transmission line,The weight of the conductor is,W=1200kg/kmThe stress is,T=1110kgThe sag…
Q: A single phase transmission line having copper conductor of 0.775 cm2 cross section over which 300…
A: A 1-ph transmission line has, Copper conductor cross sectional area (A)=0.775 square cm. Specific…
Q: A copper transmission cable (p = 1.72 × 10¬8 Nm) 250 km long and 20 cm in diameter, caries a current…
A:
Q: The puncture resistance of the insulator used in an AA cable with a conductor cross section of 150…
A: Given:Emax=200 kV/cm=200×103×102Emax=200×105 V/mArea of conductor, A=150 mm2…
Q: A 3 phase, 50Hz, Two bus, single transmission line power system consisting of line series resistance…
A: It is given that: Rse=1ohmLse=25 mHCsh=50 μF
Q: A cable is 180-miles long and has a conductor of 0.197-in in diameter with an insulation covering of…
A: In this question we need to find a capacitance of cable.
Q: 400 psoft Word (Product Activation Failed) Table Tools ences Mailings Review View Design Layout Aa…
A: Here it is ask that line charging admittance of Y bus connected between two buses is affects as
Q: Consider the simple power system shown in Fig. Q1, where impedances are expressed in per unit on 100…
A:
Q: roblem 12. A cable has the following primary constants: resistance R= 80 $2/loop km, conductance,…
A: Given a cable has the following primary constants: Resistance, R=80 Ωloop km Conductance, G=2 μSloop…
Q: Q2: A string of 4 insulators has pin-to-earth equal to 0.2 of self-capacitance. Calculate (i) the…
A:
Q: The outer radius of a coaxial cylindrical electrode system is given in 32 cm. The system is the most…
A: Given : The outer radius of a concentric spherical electrode system r2=32 cm The strength of gas…
Q: 1. A boatman rows to a place 48 km distant and back in 14 hours; he finds that he can rous 4 km with…
A: As per company guidelines we are supposed to answer only one question. Kindly repost other questions…
Q: The span of the same leveled transmission line is 300 meters. The carrier's diameter is 15…
A:
Q: A transmission-line cable consists of 12 identical strands of aluminum, each 3 mm in diameter. The…
A: Given: No. of strands= 12, Resistivity of aluminum strand= 2.8×10-8 Ωm.
Q: 1. Using the Multi-sim, connect the circuit Shown in Fig.(2), and take Vy-10V, and R 820, R- 1002…
A: Given circuit is as shown below : All resistors are in parallel ∴ Voltage across all of them will…
Q: Electrical transmission towers are stationed at 350 m intervals and a conducting cable 2 cm in…
A: Electrical transmission towers are stationed at 350 m intervals and a conducting cable 2cm in…
Q: If Resistance of Transmission line increases percent voltage regulation will increases. Select one:…
A: Voltage drop across the transmission line is directly proportional to resistance of transmission…
Q: Q: A 3 phas e , 50 HZ Transmission line clookm) and (10 kv), delivers 50MUA, o.8 pf Lagging Long the…
A:
Q: Q3: An overhead transmission line conductor at river having two un same level towers, the height of…
A:
Q: A 132kV line with 1.956 cm diameter with 1.41 meter spacing between the polished conductors…
A:
Q: DETERMINING CAPACITY UTILIZATION AND EFFICIENCY Sara James Bakery has a plant for processing Deluxe…
A: Given: The explanation is shown as: A=148,000 rolls E=175,000 rolls 7 days per week=8 hrs per day=3…
Q: Example4/ A telephone cable with R=52.5 KO/Km , C=62 nF/Km , G=0 and L=1.1 mH/Km , find ,x ,B ,Vp…
A: The solution is given below
Q: Q6. A line charging admittance of Y bus matrix is connected between two buses its affect at each bus…
A: A line charging admittance of Ybus matrix is connected between two buses its effect at each bus is…
Q: A 3 phase, 50HZ, Two bus, single transmission line power system consisting of line series resistance…
A:
A Barangay power station supplies 60KW to a load over 2500 ft, 100mm squared, two conductor copper feeders, the resistance of which is 0.078 ohm per 1000ft. The bus bar voltage is maintained constant at 600V. Determine the maximum power which can be transmitted.
Step by step
Solved in 3 steps
- 6. A string of four suspension insulators is connected across a 285 kV line. The self-capacitance of each unit is equal to 5 times pin to earth capacitance. Calculate: (1) the potential difference across each unit, () the string efficiency. [) 27-65 kV, 33-04 kV, 43-85 kV, 60 kV (if) 68-5%]A string of suspension insulators consists of three units. The capacitance between each link pin and earth is one-sixth of the self-capacitance of each unit. If the maximum voltage per unit is not to exceed 35 kV, determine the maximum voltage that the string can withstand. Also calculate the string efficiency. [84-7 kV; 80-67%]There are 144 fuel cells are joined in a series through interconnects.there will be 4 stacks having 36 cell in each stack.these stacks are then oragnised in series and parallel combination to form a single module to deliver required voltage and output power.this SOFCs module then combined with CHP system to get thermal . From this data answer the following questions. a)Calculate voltage losses of module?.this question is very compulsory. b)Electrical efficiency of module? C)Thermal efficiency when module combine with CHP system? D)Combined electrical and thermal efficiency? The input parameters of single cell are given below: Ocv=1.020 Current density=2250mA/cm2 Power density=850mw/cm2 Cell active area= 121cm2 Net power=15kw System fuel utilization=80% Operating temp=550°c Cell voltage=0.8v Power of single cell=103 watt.
- A 33 kV, 50 Hz. 3-phase underground cable, 6 km long uses three single core cables. Each of the conductor has a diameter of 2.75 cm and the radial thickness of insulation is 0.4 cm. Determine (1) capacitance of the cable/phase (ii) charging current/phase (iii) total charging KVAR. The relative permittivity of insulation is 3.Electricity has composite demand. True False5. An earth “ground” at the base of transmission line tower has a resistance of 2 ohms. If a lightning stroke of 20,000 amperes and strikes the tower, what would be the power dissipated in the “ground”? What would be the voltage drop across the “ground” during (a)? answer asap provide soln
- In a string of three identical suspension insulator units supporting transmission line conductor.if the self capacitance of each unit is debited as C farads, The capacitance of each connector pin to ground can be taken as 0.1C farad's. If the maximum permissible voltage per unit is given as 20 kva then calculate A.maximum safe working voltage B.string efficiencyA single core concentric cable is to be manufactured for a 161kV, 50Hz transmission system. The maximum permissible safe stress is to be 16,000,000V/m (rms) and the relative permittivity, 4. Calculate the following:i) the radius of the conductor ii) the radius of the sheath iii) the capacitance of the cableAn over head transmission line supported from two towers location at the same level. The distance between the towers is 200 m. The tension in the wires is 9000 N. The weight of one meter of the conductor is 10 N. The sag of the wires is * 2.55 m 1.55 m 4.55 m 5.55 m Non of them
- A power transmission line conducts current from a 6000V generator to three loads A,B,C, the loads are located 4.7 and 10Km from the generator and absorb 60,20,100A, respectively. The resistance of the line is 0 .1ohm/Km see figure 3.21a) Calculate the tension in the loads A,B,Cb) Calculate the percentage of voltage drop between generator and load C6. A string of four suspension insulators is connected across a 285 kV line. The self-capacitance of each unit is equal to 5 times pin to earth capacitance. Calculate : (1) the potential difference across each unit, (if) the string efficiency. [) 27-65 kV, 33-04 kV, 43-85 kV, 60 kV (ii) 68-5%]) For the circuit shown, determine 2 a) Vo cVz. Power at (3uA) & (2011) Vy Зил 20ks 10MA ns-[a)15V, 20V b) 75MW, 20mW