4.1Calculate the energy capacity and the capacitance of a super capacitor consisting of X metal electrodes coated with a high surface area of Ym² type of activated carbon, separated by an extremely thin double-layer porous insulator of Z nm and relative permittivity of Q all in an electrolyte with a charging voltage of R V. 4.2 A MVA turbo-alternator is working on full load at power factor of B and efficiency of C%. find the quality of cooling air required per minute at full load, assuming that D % of the total losses are dissipated by internally circulating air. the inlet air temperature is E°C and the temperature rises to F°C. given that the specific heat of air is G and that of air at 1kg occupies 0.8 m³. G= 32 X= 6 Y= 2300 Z= 0.255 Q= 2.8 R= 3.8

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
Question

Question 4 Energy

4.1Calculate the energy capacity and the capacitance of a super capacitor consisting of X metal electrodes coated with a high surface
area of Ym² type of activated carbon, separated by an extremely thin double-layer porous insulator of Z nm and relative permittivity of
Q all in an electrolyte with a charging voltage of R V.
4.2 A MVA turbo-alternator is working on full load at power factor of B and efficiency of C%. find the quality of cooling air required per
minute at full load, assuming that D % of the total losses are dissipated by internally circulating air. the inlet air temperature is E°C and
the temperature rises to F°C. given that the specific heat of air is G and that of air at 1kg occupies 0.8 m³.
G= 32
X= 6
Y= 2300
Z= 0.255
Q= 2.8
R= 3.8
Transcribed Image Text:4.1Calculate the energy capacity and the capacitance of a super capacitor consisting of X metal electrodes coated with a high surface area of Ym² type of activated carbon, separated by an extremely thin double-layer porous insulator of Z nm and relative permittivity of Q all in an electrolyte with a charging voltage of R V. 4.2 A MVA turbo-alternator is working on full load at power factor of B and efficiency of C%. find the quality of cooling air required per minute at full load, assuming that D % of the total losses are dissipated by internally circulating air. the inlet air temperature is E°C and the temperature rises to F°C. given that the specific heat of air is G and that of air at 1kg occupies 0.8 m³. G= 32 X= 6 Y= 2300 Z= 0.255 Q= 2.8 R= 3.8
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning