A generator supplies a motor through a Y-A transformer. The generator is connected to Y side of the transformer. A fault occurs between the motor terminals and the transformer. The symmetrical components of the subtransient current in the motor flowing toward the fault are: I =-0.8-j2.6pu I =-j 2.0pu I =-j3pu From the transformer toward the Fault: I' = 0.8- j0.4pu I =-j1.0pu 1 = 0pu Assume X =X, =X, for both the motor and the generator. (a) Describe the fault type and find the prefault current, if any, in line a. (b) Determine the subtransient fault current in per unit. (c) Calculate the subtransient current in each phase of the generator in per unit taking into consideration the phase shift of the Y-A transformer.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.10P: A single-phase step-down transformer is rated 13MVA,66kV/11.5kV. With the 11.5 kV winding...
icon
Related questions
Question
A generator supplies a motor through a Y-A transformer. The generator is connected to Y side of
the transformer. A fault occurs between the motor terminals and the transformer. The
symmetrical components of the subtransient current in the motor flowing toward the fault are:
I =-0.8- j2.6pu
I =-j2.0pu
I =-j3pu
From the transformer toward the Fault:
I = 0.8– j0.4pu
I? =-j1.0pu
1 = Opu
Assume X =X,=X, for both the motor and the generator.
(a) Describe the fault type and find the prefault current, if any, in line a.
(b) Determine the subtransient fault current in per unit.
(c) Calculate the subtransient current in each phase of the generator in per unit taking into
consideration the phase shift of the Y-A transformer.
Transcribed Image Text:A generator supplies a motor through a Y-A transformer. The generator is connected to Y side of the transformer. A fault occurs between the motor terminals and the transformer. The symmetrical components of the subtransient current in the motor flowing toward the fault are: I =-0.8- j2.6pu I =-j2.0pu I =-j3pu From the transformer toward the Fault: I = 0.8– j0.4pu I? =-j1.0pu 1 = Opu Assume X =X,=X, for both the motor and the generator. (a) Describe the fault type and find the prefault current, if any, in line a. (b) Determine the subtransient fault current in per unit. (c) Calculate the subtransient current in each phase of the generator in per unit taking into consideration the phase shift of the Y-A transformer.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L